At Air Condition Parts we know our customers! Every day we help Nursing Homes, Hotels and Motels, Hospitals, Colleges and Universities locate quality PTAC Air Conditioners and PTAC Air Conditioner Parts. These industries choose us because they have grown accustomed to our extensive experience and ability to identify and find not only today’s current air conditioner parts but those hard to locate PTAC parts, and to provide them at very competitive prices!
At the state level the rebates are still substantial. For example, switching to a zoned system can get you a $100 rebate from various A/C companies, and state rebates are also included. In Pennsylvania a high-efficiency air conditioner alone can get you up to $300, and a high-efficiency complete HVAC system can see up to $1000. Maryland's incentives get up to $1,250, with a $100 rebate on a tune up of an existing system. 

Heating Repair Company


Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs while the fan is slowed as much as possible[citation needed] to reduce the evaporator temperature and therefore condense more water. When the temperature falls below a threshold, both the fan and compressor are shut off to mitigate further temperature drops;[clarification needed] this prevents moisture on the evaporator from being blown back into the room.[citation needed] When the temperature rises again,[clarification needed] the compressor restarts and the fan returns to low speed.
Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
Without proper ventilation, carbon monoxide can be lethal at concentrations of 1000 ppm (0.1%). However, at several hundred ppm, carbon monoxide exposure induces headaches, fatigue, nausea, and vomiting. Carbon monoxide binds with hemoglobin in the blood, forming carboxyhemoglobin, reducing the blood's ability to transport oxygen. The primary health concerns associated with carbon monoxide exposure are its cardiovascular and neurobehavioral effects. Carbon monoxide can cause atherosclerosis (the hardening of arteries) and can also trigger heart attacks. Neurologically, carbon monoxide exposure reduces hand to eye coordination, vigilance, and continuous performance. It can also affect time discrimination.[15]
With the split system, the evaporator coil is connected to a remote condenser unit using refrigerant piping between an indoor and outdoor unit instead of ducting air directly from the outdoor unit. Indoor units with directional vents mount onto walls, suspended from ceilings, or fit into the ceiling. Other indoor units mount inside the ceiling cavity, so that short lengths of duct handle air from the indoor unit to vents or diffusers around the rooms.

If you're currently experiencing troubles with your air conditioning, heating, or electrical units, we are ready to take care of just about any issue that may happen. Whether you need a easy restore, or if you need your air conditioning or heater to be repaired, our experienced professionals can take care of you. We are able to effectively service all brands, makes, and models.


James Harrison's first mechanical ice-making machine began operation in 1851 on the banks of the Barwon River at Rocky Point in Geelong, Australia. His first commercial ice-making machine followed in 1853, and his patent for an ether vapor compression refrigeration system was granted in 1855. This novel system used a compressor to force the refrigeration gas to pass through a condenser, where it cooled down and liquefied. The liquefied gas then circulated through the refrigeration coils and vaporized again, cooling down the surrounding system. The machine produced 3,000 kilograms (6,600 lb) of ice per day.[citation needed]
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
Over the Labor Day weekend our hot water heater decided it was time to say good bye. Since we had our fall check the week before, we called Nerthlings. I cannot say enough good things about how this situation was handled. The technician, Dwain, was knowledgeable, friendly, and quite helpful without being pushy. Our questions were answered clearly. I am never made to feel that this is something...
Tired of dealing with an inoperable furnace? Or, maybe your heating system is only heating half the rooms in your home? Whether you need a new heating system installed or an existing unit repaired, there’s only one name to know—ABC Plumbing, Heating, Cooling & Electric. With more than six decades of experience handling Chicago’s heating problems, our team at ABC has the experience and know-how to get any heating issue diagnosed and resolved quickly and efficiently.
Yes. You should expect to pay a diagnostic fee to cover the cost of the technician's visit, the diagnosis of your air conditioner's problem, and a quote for the repair options. You will be advised of the issue along with recommended options to correct it, which may include a system replacement if your unit is old or significantly damaged. If you decide to replace the system, the diagnostic fee will be credited toward your replacement purchase.
Call us today at (302) 200-4266 today to schedule a service heating system repair, replacement, installation, or tune-up services with our capable team! our team! We offer honest, upfront pricing in writing and industry leading warranties on parts and service. Find your local Horizon today to schedule heating system repair, replacement, installation, or tune-up services with our capable team!
Strongsville Heating & Air Conditioning simplifies the challenges of keeping a perfectly comfortable home. We provide convenience, cost-savings, and reliability using top of the line products, premium materials, highly skilled technicians and exceptional customer service. Whether you need a new heating/cooling installation, replacement, retrofit, routine maintenance, trustworthy repair or air quality options, count on our team of NATE-certified technicians to eliminate stress and maximize comfort. We protect your busy schedule with flexible appointments, prompt arrival and mess free completion. Strongsville Heating & Air Conditioning is always available to you for Emergency Service, 24 hours a day, 365 days a year across Strongsville & Surrounding Areas.
Fuses -- Anyone who has worked with electrical systems knows all about fuses and how they fail. They can burn out over time, may just be loose, or can blow out during an electrical storm or due to overload from another failed component. Of course, that's what they're supposed to do; they stop surges from going through and damaging the rest of the system. When a fuse fails, whatever system it was protecting will stop working.

Advice you can count on – When you have an emergency, you are not always in the position of asking questions to determine if the repairs you are receiving are what you need. At Jennings, our NATE Certified technicians will walk you through the repairs and explain why you need them. You can trust that everyone on Jennings’ staff will give you honest advice.
Because an air conditioner moves heat between the indoor coil and the outdoor coil, both must be kept clean. This means that, in addition to replacing the air filter at the evaporator coil, it is also necessary to regularly clean the condenser coil. Failure to keep the condenser clean will eventually result in harm to the compressor, because the condenser coil is responsible for discharging both the indoor heat (as picked up by the evaporator) and the heat generated by the electric motor driving the compressor.
Your comfort is a priority for us. A large part of comfortable living in Cary is not only having a functioning HVAC system, it’s also understanding who to call when you have a problem. If your air conditioner starts to fail in the middle of the Cary summer, you don’t have to stay at a friend’s for weeks on end. Or if your heater goes out during a blizzard, you don’t have to dig your heaviest blankets out of the basement. Instead, you can make an appointment with a member of our team and have him or her resolve your concerns. There is no problem in Cary you can encounter that we can’t work with you to solve. You can feel confident in knowing that you’re in qualified hands.
R407C is a zeotropic hydro-fluoro-carbon refrigerant and is a blend of difluoromethane (R32) providing the heat capacity, pentafluoroethane (R125) decreasing flammability and tetrafluoroethane (R134a) to reduce pressure. Difluoromethane serves to, pentafluoroethane andtetrafluoroethane. R407C was developed as a replacement for the ozone depleting R22.
There are a number of claims in the HVAC industry that make HVAC technicians sound like they know what they are doing, but the North American Technician Excellence (NATE) certification program is the only closed book examination and certification program, administered by a third party, that tests real world working knowledge of HVAC systems. That's why all of our service technicians complete and continue NATE certification training throughout their career with SMO.
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]

With that being said, we ask ourselves, “How do we ensure our customers that we are the company they can count on?”. It all starts with our people. Each of our team members have passed a criminal background and drug test, so you can trust them with your home and family. We are licensed and insured well beyond the minimum requirements set for by the State of Texas. Also, we provide continuous training for both the technical and customer service aspects of our industry. We do this in order to make sure that we are ready and able to serve your needs with excellence.
A vapour seal is an essential part of preventing moisture infiltration into or migration out of a critical space, such as a data processing centre or other room that contains sensitive electronic instrumentation.  Essentially, a vapour seal is a barrier that prevents air, moisture, and contaminants from migrating through tiny cracks or pores in the walls, floor, and ceiling into the critical space.  It is also used extensively on pipe insulation to prevent moisture ingress that may cause deterioration of the insulation or freezing in cold conditions.
Packaged central air conditioner – the name is a good indicator of what to expect from a packaged central air conditioner. The evaporator, compressor, and condenser are all installed in one cabinet.  This cabinet is typically placed on a roof or a concrete slab near the house’s foundation.  Packaged ones normally include electric heating coils or a natural gas furnace, which eliminates the need for a separate furnace inside.

HVAC is an important part of residential structures such as single family homes, apartment buildings, hotels and senior living facilities, medium to large industrial and office buildings such as skyscrapers and hospitals, on ships and submarines, and in marine environments, where safe and healthy building conditions are regulated with respect to temperature and humidity, using fresh air from outdoors.

HVAC Repair

×