If you are installing an AC system from scratch, your contractor should calculate the size of the cooling equipment you need by using recognized methods such as what you’ll find in the Residential Load Calculation Manual, aka Manual J, from the Air Conditioning Contractors of America (ACCA). If you already have ductwork for your heating, adding a central system can cost less.
Split-system central air conditioner – for this type of system, there are two separate cabinets. One is located outside in a metal cabinet and houses the condenser and compressor.  The second cabinet is on the inside of the house and contains the evaporator.  Typically, the indoor cabinet contains a furnace or part of a heat pump, which has the evaporator coils installed in the main supply duct of the heat pump or furnace.  This system is great for anyone who already has a furnace but no air conditioner.  It offers the most affordable option for their needs.

Reinstall the access panel and disconnect block. Turn on the circuit breaker and furnace switch. Then set the thermostat to a lower temperature and wait for the AC to start (see “Be Patient at Startup,” below). The compressor should run and the condenser fan should spin. If the compressor starts but the fan doesn’t, the fan motor is most likely shot. Shut off the power and remove the screws around the condenser cover. Lift the cover and remove the fan blade and motor (photo 7). Reinstall the blade and secure the cover. Then repower the unit and see if the fan starts. If it doesn’t, you’ve given it your best shot—it’s time to call a pro.


Keep in mind that ducts used for heating might not be the right size or in the right location for optimal cooling. Your contractor should ensure that duct sections are properly sized and that there are enough supply registers to deliver sufficient air to the right spots. Undersized ductwork can make for inefficient and noisy operation. Here’s how to keep yours humming:

Condensing furnaces use two heat exchangers, where conventional furnaces use only one. After the gas is burned to heat the primary heat exchanger, the secondary heat exchanger draws heat out of the hot exhaust gasses, cooling them to the point that the water vapor in the exhaust condenses into water. The resulting flue gases are so cool they can be vented outside via a plastic (PVC) pipe, while the condensed water is run to a floor drain. Condensing furnaces use hot surface ignition (HSI).
Heil HVAC is another one of the best air conditioner brands that doesn’t get as much love as they should. This AC brand’s tech allows different heating and cooling components  send information and synchronize performance, becoming more energy efficient and reliable overall. Heil AC products can achieve up to a 97% efficiency rating and SEER figures of 19. They also come with comprehensive 10 year warranties.
Hi reader in the U.S., it seems you use Wikipedia a lot; that's great! It's a little awkward to ask, but this Monday we need your help. If you have already donated, we sincerely thank you. We’re not salespeople, but we depend on donations averaging $16.36 and fewer than 1% of readers give. If you donate just $2.50, the price of your coffee this Monday, Wikipedia could keep thriving. Thank you.

At Knoechel Heating Company, heating and cooling isn’t just our job, it’s our passion. We’re dedicated to providing you with the top HVAC service in Zelienople. No matter the time, day or the problem, you can count on us to get the job done right. After all, Knoechel Heating Company has been servicing the community since 1947, bringing comfort to our customers all year round.


Just had a well knowledge maintenance tech from A-OK come out and maintenance my AC unit and furnace. He informed me about all my safety’s were working properly and my Freon was well charged, cleaned my coils and drain, replaced my filter and checked the temps in all my supply’s. This young mans name was Mike and I would recommend him to come out to all my friends and family’s homes for maintenance.
In the case of direct expansion equipment, the air passing over the indoor cooling coil heats the cold liquid refrigerant. Heating the refrigerant causes boiling and transforms the refrigerant from a cold liquid to a warm gas. This warm gas (or vapor) is pumped from the cooling coil to the compressor through a copper tube (suction line to the compressor) where the warm gas is compressed. In some cases, an accumulator is placed between the cooling coil and the compressor to capture unused liquid refrigerant and ensures that only vapor enters the compressor. The compression process increases the pressure of the refrigerant vapor and significantly increases the temperature of the vapor. The compressor pumps the vapor through another heat exchanger (outdoor condenser) where heat is rejected and the hot gas is condensed to a warm high pressure liquid. This warm high pressure liquid is pumped through a smaller copper tube (liquid line) to a filter (or filter/dryer) and then on to an expansion device where the high pressure liquid is reduced to a cold, low pressure liquid. The cold liquid enters the indoor cooling coil and the process repeats.

This single phase 13 SEER sweat air conditioning This single phase 13 SEER sweat air conditioning system is designed for residential and commercial applications and consists of the outdoor condenser indoor cased coil and 30 ft. line set. The compact micro-channel condenser is charged with R-410A refrigerant and has a top air discharge. The cased coil is filled ...  More + Product Details Close
In hot weather, air conditioning can prevent heat stroke, dehydration from excessive sweating and other problems related to hyperthermia. Heat waves are the most lethal type of weather phenomenon in developed countries. Air conditioning (including filtration, humidification, cooling and disinfection) can be used to provide a clean, safe, hypoallergenic atmosphere in hospital operating rooms and other environments where proper atmosphere is critical to patient safety and well-being. It is sometimes recommended for home use by people with allergies.

Furnace Repair

×