Advantages of the ductless system include smaller size and flexibility for zoning or heating and cooling individual rooms. The inside wall space required is significantly reduced. Also, the compressor and heat exchanger can be located farther away from the inside space, rather than merely on the other side of the same unit as in a PTAC or window air conditioner. Flexible exterior hoses lead from the outside unit to the interior one(s); these are often enclosed with metal to look like common drainpipes from the roof. In addition, ductless systems offer higher efficiency, reaching above 30 SEER.[39]
Indoor Fan Motor -- Indoor fans circulate the air from your house and through the system. Age and dust buildup are the two biggest contributing factors to their failure. When they are starting to fail they will often make noise. Failure of the fan will result in no heating or cooling, and if it is not repaired soon, it can cause other components to fail.

In the case of direct expansion equipment, the air passing over the indoor cooling coil heats the cold liquid refrigerant. Heating the refrigerant causes boiling and transforms the refrigerant from a cold liquid to a warm gas. This warm gas (or vapor) is pumped from the cooling coil to the compressor through a copper tube (suction line to the compressor) where the warm gas is compressed. In some cases, an accumulator is placed between the cooling coil and the compressor to capture unused liquid refrigerant and ensures that only vapor enters the compressor. The compression process increases the pressure of the refrigerant vapor and significantly increases the temperature of the vapor. The compressor pumps the vapor through another heat exchanger (outdoor condenser) where heat is rejected and the hot gas is condensed to a warm high pressure liquid. This warm high pressure liquid is pumped through a smaller copper tube (liquid line) to a filter (or filter/dryer) and then on to an expansion device where the high pressure liquid is reduced to a cold, low pressure liquid. The cold liquid enters the indoor cooling coil and the process repeats.


Building Energy Management System is a computer-based control system installed in buildings that controls and monitors the building’s mechanical and electrical equipment such as ventilation, lighting, power systems, fire systems, and security systems. Designed to enhance system performance, drive down operational costs and aid decision making. Also see ACIS™.
A specialized air conditioner that is used only for dehumidifying is called a dehumidifier. It also uses a refrigeration cycle, but differs from a standard air conditioner in that both the evaporator and the condenser are placed in the same air path. A standard air conditioner transfers heat energy out of the room because its condenser coil releases heat outside. However, since all components of the dehumidifier are in the same room, no heat energy is removed. Instead, the electric power consumed by the dehumidifier remains in the room as heat, so the room is actually heated, just as by an electric heater that draws the same amount of power.
The most common type of central air conditioning is the split system, which features a large, boxy condenser outside the home and a fan-and-coil system inside, connected by pipes carrying refrigerant. The air is distributed through ductwork. However, not every home can accommodate the ductwork needed to install central air. Split ductless systems are an option for those homes because, as the name indicates, they don’t require ductwork.
Acosta Heating & Cooling is your one-stop-shop for all of your indoor comfort needs. We’ve been serving the Charlotte area for over 45 years, and our customers are always treated with respect and professionalism. But with so many air conditioning and heating companies out there, how are you supposed to choose? It all starts with how a company treats their customers. Here at Acosta Heating & Cooling, you’ll always be treated like family. From a quick furnace repair to comprehensive air conditioning service, Acosta will always deliver. See below for some reasons why we’re the best air conditioning and heating service company in Charlotte and surrounding areas:
With that being said, we ask ourselves, “How do we ensure our customers that we are the company they can count on?”. It all starts with our people. Each of our team members have passed a criminal background and drug test, so you can trust them with your home and family. We are licensed and insured well beyond the minimum requirements set for by the State of Texas. Also, we provide continuous training for both the technical and customer service aspects of our industry. We do this in order to make sure that we are ready and able to serve your needs with excellence.
Thank you Caleb Elliott for servicing our water heater. We are ready for winter! Caleb was very personable and did a thorough job servicing our water heater. We appreciate Reliable's commitment to service and keeping things running for us. Every service person we've had has been top notch. So glad we chose Reliable to take care of us. Continue reading...
ISO 16813:2006 is one of the ISO building environment standards.[29] It establishes the general principles of building environment design. It takes into account the need to provide a healthy indoor environment for the occupants as well as the need to protect the environment for future generations and promote collaboration among the various parties involved in building environmental design for sustainability. ISO16813 is applicable to new construction and the retrofit of existing buildings.[30]
High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.
When it comes to heater repair in Denver, a properly serviced system means significant savings for the homeowner. When a Denver heating technician inspects your system before the winter sets in, the first thing they will check is the condition of the air filters. These filters are important, because they are responsible for removing contaminants, allergens, and dust particles from the air every time the system is turned on. When the filters are clogged, expect more particles to easily pass through right into the air you breathe inside the home. The Denver heating experts will inspect and replace any filters that are no longer effective.
A packaged system is a single unit combining all the components described in the split system. Since the unit is a package, it must be placed outside the building and indoor air is “ducted” from the building to the packaged system and back through an air distribution system. These units typically have SEER rating from 10 to 18. If heating is required, an alternate method of heating the interior of the building must be used, usually in the form of electric or gas heating.
×