Ground source, or geothermal, heat pumps are similar to ordinary heat pumps, but instead of transferring heat to or from outside air, they rely on the stable, even temperature of the earth to provide heating and air conditioning. Many regions experience seasonal temperature extremes, which would require large-capacity heating and cooling equipment to heat or cool buildings. For example, a conventional heat pump system used to heat a building in Montana's −70 °F (−57 °C) low temperature or cool a building in the highest temperature ever recorded in the US—134 °F (57 °C) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air temperatures. A few feet below the earth's surface, however, the ground remains at a relatively constant temperature. Utilizing this large source of relatively moderate temperature earth, a heating or cooling system's capacity can often be significantly reduced. Although ground temperatures vary according to latitude, at 6 feet (1.8 m) underground, temperatures generally only range from 45 to 75 °F (7 to 24 °C).

The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
This single phase 13 SEER sweat air conditioning This single phase 13 SEER sweat air conditioning system is designed for residential and commercial applications and consists of the outdoor condenser indoor cased coil and 30 ft. line set. The compact micro-channel condenser is charged with R-410A refrigerant and has a top air discharge. The cased coil is filled ...  More + Product Details Close
Air Conditioning Parts is an international AC Parts distributor specializing in OEM wholesale A/C Parts for all air conditioner makes and models. All of our parts and equipment are available at factory direct pricing! For almost 30 years, our exceptional level of service and responsiveness coupled with our experienced air conditioning parts specialists have allowed us to establish solid long term relationships with thousands of A/C service companies, hotel and motel owners, apartment owners and management companies, and numerous other industry professionals who need and count on a knowledgeable AC parts supplier for the right part, overnight delivery and the best possible prices for all types of air conditioning parts and AC equipment. Professionals know they can depend on Air Conditioner Parts! Let us earn your trust. Call us for any A/C Part or any A/C Equipment at 800-525-3572.
Humidity is becoming more of a concern to building operators and owners. High indoor humidity leads to mold and mildew growth inside the building. The are several methods of controlling indoor humidity. The simplest (and most expensive) method is to connect a humidistat to an electric heater. When the humidity inside the building rises above the humidistat set point, the heater is turned on. The additional heat causes the air conditioning system to run longer and remove more moisture.
Our professional AC Repair technicians are certified and well trained to handle all of your AC repair and air conditioning needs including: Central Air Conditioner. Split System. Ductless Mini Split Air Conditioner. Through The Wall Air Conditioner. Indoor Packaged Units and Rooftop Packaged Units. For Same Day Air Conditioner Repair And Installation Service Call 215.725.6111
An air conditioning system, or a standalone air conditioner, provides cooling and humidity control for all or part of a building. Air conditioned buildings often have sealed windows, because open windows would work against the system intended to maintain constant indoor air conditions. Outside, fresh air is generally drawn into the system by a vent into the indoor heat exchanger section, creating positive air pressure. The percentage of return air made up of fresh air can usually be manipulated by adjusting the opening of this vent. Typical fresh air intake is about 10%.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
Ventilation is the process of changing or replacing air in any space to control temperature or remove any combination of moisture, odors, smoke, heat, dust, airborne bacteria, or carbon dioxide, and to replenish oxygen. Ventilation includes both the exchange of air with the outside as well as circulation of air within the building. It is one of the most important factors for maintaining acceptable indoor air quality in buildings. Methods for ventilating a building may be divided into mechanical/forced and natural types.[16]
Indoor Coil -- The indoor coil is a heat transfer device. It absorbs the heat from the inside of the house and passes it on to the refrigerant and is pumped outside. Dust that builds up on the coil can hamper its ability to absorb heat. High heat transference coils use very thin metal. Airborne chemicals can cause corrosion which leads to leaks. The constant vibration of the compressor can also cause solder joints to weaken and leak. An indoor coil may operate for weeks with a tiny leak, and you may not notice the loss in performance right away. As soon as a leak is made known, it should be replaced or repaired immediately.
"I was experiencing problems with one of my rooms not getting enough air flow, I was reached out to and they got a better feel for what my situation was and gave me the best honest opinion about what I should do, I really appreciate their professionalism in the manner and not just trying to gain my business. They really looked out for me as a customer, and I couldn’t be more grateful!"

At Welzig Heating & Air, we focus on quality.  Recognizing that a cut corner today results in long-term problems and expense, we adhere to strict procedures for service and installation, and recommend only premier products.  While we provide affordable solutions to indoor comfort, we refuse to compromise integrity with subpar equipment, materials, or workmanship.  If you’re looking for residential or commercial heating, cooling, air quality, or water heating services of a higher caliber, Welzig Heating & Air delivers satisfaction across Boulder, CO & Surrounding Areas.  Contact us at 303-678-5576 anytime you need us.  Our dedicated technicians are on-call, ready to handle any challenge, 24 hours a day, 365 days a year.
Our goal is to make you more comfortable in your home. When your furnace, central air conditioner, heat pump or boiler stops working and you need service, call the professionals at BGE HOME. Heating and cooling system breakdowns occur at the most inconvenient times, so rely on our certified, skilled technicians to make the repair quickly and correctly the first time.
This may apply to a system using fresh air for cooling the space or a water cooled or glycol cooled system with an additional coil that provides chilled water cooling when the outdoor ambient is cold; thereby reducing or eliminating compressor operation. These systems may provide free cooling for up to 80% of their operating life, particularly when operating in Northerly climates. See our Free Cooling page for more information.
A split system is a combination of an indoor air handling unit and an outdoor condensing unit. The indoor air handling unit contains a supply air fan and an air-to-refrigerant heat exchanger (or cooling coil), and the expansion device. The outdoor condensing unit consists of a compressor and a condenser coil. Split-systems are typically found in residential or small commercial buildings. These systems have the highest energy efficiency rating (EER) of all the available AC systems. Manufacturers are required to take the EER rating a step further and provide a seasonal energy efficiency rating (SEER) for use by consumers. SEER ratings vary widely and range from 10 to 20. The higher the SEER rating, the more efficient the AC system operates. If heating is required, an alternate method of heating the interior of the building must be used, usually in the form of electric or gas heating.
In hot weather, air conditioning can prevent heat stroke, dehydration from excessive sweating and other problems related to hyperthermia. Heat waves are the most lethal type of weather phenomenon in developed countries. Air conditioning (including filtration, humidification, cooling and disinfection) can be used to provide a clean, safe, hypoallergenic atmosphere in hospital operating rooms and other environments where proper atmosphere is critical to patient safety and well-being. It is sometimes recommended for home use by people with allergies.

Furnace Repair

×