For complex commercial heating and cooling systems, you need an expert. When you run into malfunctions, it’s not a DIY job to fix it. At Air Blue Heating and Cooling Inc., we know how important your HVAC systems are to running your commercial facility. Anytime you need repairs, maintenance, or installations, contact our team of licensed professionals. With our extensive industry background, we provide the highest quality service for your systems. We always adhere to strict standards for procedures, training, and customer service. As a Carrier Factory Authorized Dealer, we meet rigid standards for customer service and technical expertise, so you know you’re getting the very best. Give us a call any time of the day for efficient, accurate, and long-lasting commercial HVAC services in Elk Grove Village, Addison, Bedford Park, Bensenville, Elmhurst, Chicagoland and the surrounding suburbs.
The cost of a new furnace might make you balk at first thought, but with modern manufacturers offering an extremely diverse range of options with varying AFUE ratings, optional accessories, and more, there is a furnace to meet any budget! It’s just important that you work with the right service team and experts that will work with you rather than try to “sell” you.
The Chartered Institution of Building Services Engineers is a body that covers the essential Service (systems architecture) that allow buildings to operate. It includes the electrotechnical, heating, ventilating, air conditioning, refrigeration and plumbing industries. To train as a building services engineer, the academic requirements are GCSEs (A-C) / Standard Grades (1-3) in Maths and Science, which are important in measurements, planning and theory. Employers will often want a degree in a branch of engineering, such as building environment engineering, electrical engineering or mechanical engineering. To become a full member of CIBSE, and so also to be registered by the Engineering Council UK as a chartered engineer, engineers must also attain an Honours Degree and a master's degree in a relevant engineering subject.
Air Blue Heating and Cooling Inc. protects your safety and investment with unwavering dedication.  We are available 24 hours a day, 365 days a year, for reliable Emergency Service, and as a local company we respond quickly to any crisis anywhere in Chicagoland and the surrounding suburbs, including Wheeling, Buffalo Grove, Northbrook, Deerfield, IL.  Our trucks are fully stocked with leading-edge diagnostic equipment, specialized tools, and genuine factory authorized parts to accurately identify and resolve even complex problems without delay.  We recognize the importance of a properly operating heating and cooling system to both your home and commercial facility, and never leave you waiting for a tardy technician or distant appointment time.  By offering same day service and installation, courteous customer service, and affordable pricing, we strive to make your life easier.

R22 (also known as HCFC-22) has a global warming potential about 1,800 times higher than CO2.[61] It was phased out for use in new equipment by 2010, and is to be completely discontinued by 2020. Although these gasses can be recycled when air conditioning units are disposed of, uncontrolled dumping and leaking can release gas directly into the atmosphere.


HVAC professionals in the US can receive training through formal training institutions, where most earn associate degrees. Training for HVAC technicians includes classroom lectures and hands-on tasks, and can be followed by an apprenticeship wherein the recent graduate works alongside a professional HVAC technician for a temporary period.[31] HVAC techs who have been trained can also be certified in areas such as air conditioning, heat pumps, gas heating, and commercial refrigeration.[32]
R-22 Freon is being phased out & isn't readily available. So the service company may only purchase as needed and the lack of availability would make their cost high. But, as long as they can get it, whatever the cost, unfortunately, is less expensive than replacing the A/C. Which will be the case eventually since it's no longer manufactured or sooner as in my case with a not so old a/c that sprang a leak, that would have been just a repair, but since it uses R-22 the whole unit has to be upgraded(replaced).  
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
The manufacture and use of CFCs has been banned or severely restricted due to concerns about ozone depletion (see also Montreal Protocol).[63][64] In light of these environmental concerns, beginning on November 14, 1994, the U.S. Environmental Protection Agency has restricted the sale, possession and use of refrigerant to only licensed technicians, per rules under sections 608 and 609 of the Clean Air Act.[65]
Central heating systems have a primary heating appliance, such as a furnace, typically located in your basement or garage. All furnaces consist of four main components: 1) burners that deliver and burn fuel, 2) heat exchangers, 3) a blower and 4) a flue that acts as an exhaust for gaseous by-products. Depending on your situation, region and needs, you can choose from heating systems running on either gas or oil as fuel, or a hybrid packaged system that can use both fuel types.

As a full-service heating contractor, we strongly encourage you to be vigilant with annual heating maintenance. Without proper maintenance, a heat pump, furnace or boiler might last only half as long as a well-maintained unit. Don’t tempt fate by skimping on annual service. We offer an economical, yet comprehensive maintenance agreement that we call our Cool Care Service Agreement. With our maintenance agreement you’ll receive:

When the thermostat calls for heat, 24 volts are sent to the electronic ignition control module, which energizes the furnace blower and other systems and sends 120 volts to the HSI. The HSI heats up to around 1,800°F to 2,500°F and glows red-hot. Then the gas valve opens, and the burner gas is ignited by the HSI. Once a proper flame is sensed by the flame sensor, the HSI turns off and stays off until the next heating cycle. In some furnaces, the HSI also serves as a flame sensor (called local sensing) instead of having a separate sensing rod in the burner flame (remote sensing).

At Comfort Plus Services, we set ourselves apart from the rest through quality customer service across Salisbury, MD and surrounding areas. See our Areas of Service. Our strength is in our high standards of job performance and fully trained professionals.  Our team upholds a proven reputation and is continually motivated to achieve excellence in every service we provide.


Hospital operating theatres, in which air is filtered to high levels to reduce infection risk and the humidity controlled to limit patient dehydration. Although temperatures are often in the comfort range, some specialist procedures, such as open heart surgery, require low temperatures (about 18 °C, 64 °F) and others, such as neonatal, relatively high temperatures (about 28 °C, 82 °F).
As this liquid passes through the indoor cooling coil on the inside of the heat exchanger, two things happen to the air that passes over the coil’s surface on the outside of the heat exchanger. The air’s temperature is lowered (sensible cooling) and moisture in the air is removed (latent cooling) if the indoor air dew point is higher than the temperature of the coil’s surface. The total cooling (capacity) of an AC system is the sum of the sensible and latent cooling. Many factors influence the cooling capacity of a DX air conditioner. Total cooling is inversely proportional to outdoor temperature. As the outdoor temperature increases the total capacity is reduced. Air flow over the indoor cooling coil also affects the coil’s capacity and is directly proportional to the total capacity of an AC system. As air flow increases, the total capacity also increases. At higher air flow rates the latent capacity of the cooling coil is reduced. Indoor temperature and humidity also affect the total capacity of the AC system. As indoor temperatures increase, the sensible capacity also increases. Similarly, as indoor relative humidity increases the latent capacity of the AC system increases. Manufacturers of AC equipment typically provide a “performance map” of specific equipment to show how total, sensible, and latent capacity change with changing indoor and outdoor temperatures and humidity. Power consumption and energy efficiency are also provided in these charts.
Air flow meter Aquastat BACnet Blower door Building automation Carbon dioxide sensor Clean Air Delivery Rate (CADR) Gas sensor Home energy monitor Humidistat HVAC control system Intelligent buildings LonWorks Minimum efficiency reporting value (MERV) OpenTherm Programmable communicating thermostat Programmable thermostat Psychrometrics Room temperature Smart thermostat Thermostat Thermostatic radiator valve
Call us today at (302) 200-4266 today to schedule a service heating system repair, replacement, installation, or tune-up services with our capable team! our team! We offer honest, upfront pricing in writing and industry leading warranties on parts and service. Find your local Horizon today to schedule heating system repair, replacement, installation, or tune-up services with our capable team!
This single phase 13 SEER sweat air conditioning This single phase 13 SEER sweat air conditioning system is designed for residential and commercial applications and consists of the outdoor condenser indoor cased coil and 30 ft. line set. The compact micro-channel condenser is charged with R-410A refrigerant and has a top air discharge. The cased coil is filled ...  More + Product Details Close
Whether it’s AC repair or total AC system replacement, there are various terms within the HVAC industry that can get confusing for homeowners. Not to mention all of the different pieces of heating and air conditioning equipment that can be used to boost your home’s energy efficiency and air quality. Of course we can’t write about all of the variations in a short blog post, so we’ll take a look at one of the routine inquiries we see at Service Experts Heating & Air Conditioning: what’s the difference between an air conditioner and an air handler?

HVAC Repair Company

×