Having the most energy-efficient system ever built won't matter much if it's not maintained. Lack of maintenance is the number one killer of HVAC systems. Before each cooling season, it's recommended that your system get a professional tune-up. However, there are things you can do in the meantime to make sure your system runs efficiently throughout the year.
If you have a heating or cooling emergency, call Vredevoogd Heating & Cooling Grand Rapids MI, Furnace Repair Lansing, Furnace Repair Kalamazoo and more at 616-828-5411. When you call you speak directly with one of our service representatives about the problem you are experiencing and schedule a service appointment. Naturally, we prioritize emergencies so you can count on us when your heating or cooling systems fail. After regular business hours, you can reach our customer service staff who will report your problem to on-call technicians. You can expect to hear back from a certified tech within 15 minutes of your call. Your heating and cooling emergency is important to us. We will visit your home ASAP to provide you with the superior service you’d expect from a Furnace Repair, Air Conditioning, AC Repair & HVAC leader like Vredevoogd Heating & Cooling Grand Rapids, AC Repair Lansing, AC Repair Kalamazoo.

A split system is a combination of an indoor air handling unit and an outdoor condensing unit. The indoor air handling unit contains a supply air fan and an air-to-refrigerant heat exchanger (or cooling coil), and the expansion device. The outdoor condensing unit consists of a compressor and a condenser coil. Split-systems are typically found in residential or small commercial buildings. These systems have the highest energy efficiency rating (EER) of all the available AC systems. Manufacturers are required to take the EER rating a step further and provide a seasonal energy efficiency rating (SEER) for use by consumers. SEER ratings vary widely and range from 10 to 20. The higher the SEER rating, the more efficient the AC system operates. If heating is required, an alternate method of heating the interior of the building must be used, usually in the form of electric or gas heating.
Our professional AC Repair technicians are certified and well trained to handle all of your AC repair and air conditioning needs including: Central Air Conditioner. Split System. Ductless Mini Split Air Conditioner. Through The Wall Air Conditioner. Indoor Packaged Units and Rooftop Packaged Units. For Same Day Air Conditioner Repair And Installation Service Call 215.725.6111

SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
R22 (also known as HCFC-22) has a global warming potential about 1,800 times higher than CO2.[61] It was phased out for use in new equipment by 2010, and is to be completely discontinued by 2020. Although these gasses can be recycled when air conditioning units are disposed of, uncontrolled dumping and leaking can release gas directly into the atmosphere.
This single phase 13 SEER sweat air conditioning This single phase 13 SEER sweat air conditioning system is designed for residential and commercial applications and consists of the outdoor condenser indoor cased coil and 30 ft. line set. The compact micro-channel condenser is charged with R-410A refrigerant and has a top air discharge. The cased coil is filled ...  More + Product Details Close
Induced draft furnaces use a small fan to draw the combustion gasses from the combustion chamber and out of the house through the flue (chimney). This system is more reliable and safer than old conventional furnaces, which relied on a natural draft coming in from an opening at the front of the furnace. Induced draft furnaces use either an intermittent pilot (IP) or hot surface ignition (HSI) instead of a standing pilot light. The combination of electronic ignition, electronic controls, and artificially created draft improves the efficiency of induced draft furnaces over older conventional models. 
Need 24-hour emergency furnace repair? We can provide that too. With our same-day service and live phone and online chat service available 24/7, we make your comfort our top priority. Heating and air conditioning should help you live a comfortable life, so let us help you make your home the most comfortable it has ever been. It’s easy, just grab your furnace repair coupon, then simply give us a call at 615-953-9885, chat or schedule an appointment with us online.
Heat pipe heat exchangers or run-around coils perform a similar function when humidity control is required. Two heat exchanger are placed in the air stream, one upstream of the cooling coil and the other downstream of the cooling coil. These heat exchangers are connected together with piping. A heat transfer fluid, whether it be water or refrigerant, is either pumped or gravity fed from one heat exchanger to the other. The heat exchanger down stream of the cooling coil (re-heat coil) cools the liquid medium inside the heat exchanger and heats the air passing over the heat exchanger. The cold liquid inside the heat exchanger is moved to the heat exchanger upstream of the cooling coil (pre-cool coil) where it pre-cools the air passing over the heat exchanger and warms the liquid passing through the heat exchanger. The affect of a heat pipe or run-around coil is to reduce the sensible heat capacity of the AC system. The latent capacity of the AC system increases if direct-expansion equipment is used or remains relatively constant if chilled water equipment is used. Since the sensible capacity of the AC system has been reduced, the system must run longer to meet the thermostat set point thereby removing more moisture.
Air Blue Heating and Cooling Inc. provides a full range of residential and commercial heating, cooling, and air quality services across Chicagoland and the surrounding suburbs.  With over thirty years of practical experience, we know exactly how to protect your comfort, wallet, and enjoyment of your indoor space.  As a Carrier Factory Authorized Dealer, we ensure top quality products and maximize performance through skilled services.  Our team is fully licensed, bonded, insured, and factory trained.  Every call is answered by a NATE-certified professional, who has verified technical excellence through strenuous, industry-recognized exams.
Getting one of the best air conditioner brands is important whether you’re replacing an old HVAC system, or having the first AC unit system put in your brand new home, but it’s not everything. The best Trane, Ruud, or American Standard HVAC system won’t perform any better than a no-name bargain air conditioner system if it’s not installed properly by a quality HVAC contractor. It’s important to find an HVAC installation professional with high ratings and expert knowledge within the field so that your top brand can perform at optimal efficiency.
A packaged system is a single unit combining all the components described in the split system. Since the unit is a package, it must be placed outside the building and indoor air is “ducted” from the building to the packaged system and back through an air distribution system. These units typically have SEER rating from 10 to 18. If heating is required, an alternate method of heating the interior of the building must be used, usually in the form of electric or gas heating.
×