Mitsubishi Electric is a world leader in air conditioning systems for residential, commercial and industrial use. Challenged to create air conditioning systems that provide exemplary performance in the wide-ranging climatic conditions found throughout Japan, our engineers develop amazingly sophisticated yet durable units and systems capable of constant use under virtually any natural climatic condition on earth.
Don’t forget, when you’re in the need for 24 HR emergency repair in Akron, Ohio, Jennings is there for you no matter the time of day or night—24 hours a day and 7 days a week. If you have an emergency, please call 330-784-1286 now. If you would like to request service, please fill out and submit the form below and a Jennings associate will be in touch make an appointment.
An air conditioner's compressor contains a refrigerant. As it works, it sends this refrigerant through the system. As warm air blows across the coil that carries this refrigerant, the heat transfers to the refrigerant (cool always absorbs warm). A fan moves the cooled air through the ducting and out of vents that lead into the rooms of your house. The refrigerant returns to the compressor where the absorbed heat is moved outside. The refrigerant is then sent through the coil once again to continue the cycle.
Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
Air-source heat pumps are more popular in milder winter climates where the temperature is frequently in the range of 4–13 °C (40–55 °F), because heat pumps become inefficient in more extreme cold. This is because ice forms on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to being the condenser coil, so that it can heat up and defrost. A heat pump system will therefore have a form of electric resistance heating in the indoor air path that is activated only in this mode in order to compensate for the temporary indoor air cooling, which would otherwise be uncomfortable in the winter.
An energy recovery ventilator: This component helps improve the air inside your home by swapping it out with fresh air from the outside. During the winter months when houses are closed up to keep out the cold, the air inside becomes a handy way for colds and flu to infect an entire family. By circulating outside air inside, the health of your family will have a better chance.
Read what our many satisfied customers say about Moncrief. We consistently receive 5-star reviews from both our commercial and residential customers. Moncrief's legacy of comfort and trust, as well as our great team and customer service are second to none. Contact us today to schedule an appointment or inquire about our Total Comfort Service Plan. Moncrief Heating & Air Conditioning is the company to provide the services you need in Roswell and Marietta. Call us at 404-350-2300.

Furnace & Heating repair, installation and maintenance provided by TRS Heating and Air Conditioning will keep your house cosy and your energy bills in check. If you’re in the area TRS Heating and Air Conditioning can make sure your home heating system is running at it’s maximum potential. Making sure your furnace and home heating is running efficiently is extremely important in providing your home with stable temperatures all year round.


In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.


If you are installing an AC system from scratch, your contractor should calculate the size of the cooling equipment you need by using recognized methods such as what you’ll find in the Residential Load Calculation Manual, aka Manual J, from the Air Conditioning Contractors of America (ACCA). If you already have ductwork for your heating, adding a central system can cost less.

The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).


Nerthlings Heating and Air Conditioning is proud to be rated as Erie, PA’s leading heating and cooling company. We’ve been serving Erie PA and the surrounding areas for over 60 years, handling all of their HVAC needs. For furnace repair, furnace service, or a new heating system installation at your home/business, Nerthling’s is the company to call if you want the job done right. We are also experts at AC repair, service & installation, as well as generator installation. Our other services include boiler repair and service, geothermal HVAC, heat pumps and ductless heating & air conditioning. To learn more about our high-quality HVAC services, give us a call today at 814-240-2297!

HVAC Repair Co

×