An improperly maintained heating and air conditioning is an inefficient heating and air conditioning system. That’s why we provide appointments for annual inspections with our licensed technicians. It’s our goal to make sure that your home is as comfortable and energy-efficient as possible. For inspections, repairs, and service, contact BGE HOME for quality service.
The use of CFC as a refrigerant was once common, including the refrigerants R-11 and R-12 (sold under the brand name Freon-12). Freon refrigerants were commonly used during the 20th century in air conditioners due to their superior stability and safety properties. When they are released accidentally or deliberately, these chlorine-bearing refrigerants eventually reach the upper atmosphere.[60] Once the refrigerant reaches the stratosphere, UV radiation from the Sun homolytically cleaves the chlorine-carbon bond, yielding a chlorine radical. These chlorine radicals catalyze the breakdown of ozone into diatomic oxygen, depleting the ozone layer that shields the Earth's surface from strong UV radiation. Each chlorine radical remains active as a catalyst until it binds with another radical, forming a stable molecule and quenching the chain reaction.
At the first sign your HVAC system is not working properly, you should call us to schedule an appointment with one of our NATE-certified technicians. The longer you wait to have that strange noise or smell checked out, it could lead to higher repair bills or HVAC system failure. Don't wait until it is too late and you are without your heating or cooling equipment. Catching the problem early on could save you hundreds of dollars in repair bills.
In hot weather, air conditioning can prevent heat stroke, dehydration from excessive sweating and other problems related to hyperthermia. Heat waves are the most lethal type of weather phenomenon in developed countries. Air conditioning (including filtration, humidification, cooling and disinfection) can be used to provide a clean, safe, hypoallergenic atmosphere in hospital operating rooms and other environments where proper atmosphere is critical to patient safety and well-being. It is sometimes recommended for home use by people with allergies.

When a gas furnace is not in operation, most send a steady, wasteful draft of warm household air traveling up the venting system and out the roof. The Rheem Classic® Series and Classic® Plus Lines – with AFUE ratings of 78% and better – feature an induced-draft blower that works in conjunction with a hot surface ignition system to pull hot gases through the heat exchanger at a constant and controlled rate of flow. As the burner cycles off, the draft blower stops, keeping the heating air in the system.
Air Handling Unit (AHU): a device used to condition and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blower, heating or cooling elements, filter racks or chambers, sound attenuators, and dampers. Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
Bigger is not necessarily better when it comes to HVAC systems, and smaller isn't always more efficient. If you have too small of a system, your system will be running constantly as it tries to keep up with the temperature. If you have too large of a system, it won't run long enough to keep up with the humidity. In order to handle both temperature and humidity efficiently, an HVAC system should run for around 30 minutes at a time. If your system is staying on too long or shutting off after only around 10 minutes, you are not getting efficient performance.

Here’s what you should know about air handlers: if you’re searching for a conventional furnace or air conditioner, you’ll likely never need to know what an air handler is because it’s probable you won’t need one. However, if you’re in the market for an electric heat pump, it’s helpful to know that an air handler will probably be a part of your home’s HVAC system.
Roof-mounted systems have the heating and cooling systems in one cabinet. Sometimes called "gas packs" (if the heater uses natural gas), they typically cost less than a comparable split system. In dry regions, most homes originally had "swamp-coolers" installed. When replacing them with HVAC systems, it's often cheaper to use existing mounts and ducting.
Energy efficiency can be improved even more in central heating systems by introducing zoned heating. This allows a more granular application of heat, similar to non-central heating systems. Zones are controlled by multiple thermostats. In water heating systems the thermostats control zone valves, and in forced air systems they control zone dampers inside the vents which selectively block the flow of air. In this case, the control system is very critical to maintaining a proper temperature.
Air conditioners often use a fan to distribute the conditioned air to an occupied space such as a building or a car to improve thermal comfort and indoor air quality. Electric refrigerant-based AC units range from small units that can cool a small bedroom, which can be carried by a single adult, to massive units installed on the roof of office towers that can cool an entire building. The cooling is typically achieved through a refrigeration cycle, but sometimes evaporation or free cooling is used. Air conditioning systems can also be made based on desiccants (chemicals which remove moisture from the air) and subterraneous pipes that can distribute the heated refrigerant to the ground for cooling.[2]
In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.
The Rack Cooling Index (RCI) is a metric that measures the percentage of racks in the data centre where the air inlet temperature is at the recommended or allowable level under the guidelines put forth by ASHRAE. RCI (hi) is the metric for racks at the upper limit and RCI (lo) for racks at the lower limit. This metric reveals how uniformly and efficiently a data centre is being cooled.
Induced draft furnaces use a small fan to draw the combustion gasses from the combustion chamber and out of the house through the flue (chimney). This system is more reliable and safer than old conventional furnaces, which relied on a natural draft coming in from an opening at the front of the furnace. Induced draft furnaces use either an intermittent pilot (IP) or hot surface ignition (HSI) instead of a standing pilot light. The combination of electronic ignition, electronic controls, and artificially created draft improves the efficiency of induced draft furnaces over older conventional models. 

Cold aisle is a layout design for server racks and other computing equipment in a data centre. Cold aisle data center design involves lining up server racks in alternating rows with cold air intakes facing one way and hot air exhausts facing the other. The rows composed of rack fronts are called cold aisles. See Data Centre Aisle Containment for more information.
Fresh-Aire UV is an innovation leader in the field of indoor air quality. Our award-winning UV light and carbon products fight mold, bacteria, viruses and odors in commercial and residential HVACR systems. Our products include Blue-Tube UV®, the world’s most popular germicidal UV light, the revolutionary APCO® PCO/carbon whole-house air purifier, and Mini UV the first UV light system designed specifically for mini-split AC systems.
Service Experts Heating and Air Conditioning was built with the determination of delivering customers with the most excellent heating and cooling practices in the industry. Since its foundation, Donelson Air Service Experts in Nashville has been faithful to community, offering the first class HVAC (Heating, Ventilation, Air Conditioning) products and services in the area. If you are interested in more information about your regional HVAC leaders, give us a call at 615-953-9885 or set up an appointment with us online.
The chill of winter can be a scary thought when your furnace needs repair. When the furnace in your home goes on the fritz, you need it fixed right away to keep your family safe and comfortable. Every BGE HOME technician is licensed and adheres to a stringent in-house certification program that guarantees their knowledge, affirms their commitment to the customer, and ensures excellence in completing every furnace repair with the highest level of quality.
The compressor-based refrigerant systems are air-cooled, meaning they use air to exchange heat, in the same way as a car radiator or typical household air conditioner does. Such a system dehumidifies the air as it cools it. It collects water condensed from the cooled air and produces hot air which must be vented outside the cooled area; doing so transfers heat from the air in the cooled area to the outside air.
×