R407C is a zeotropic hydro-fluoro-carbon refrigerant and is a blend of difluoromethane (R32) providing the heat capacity, pentafluoroethane (R125) decreasing flammability and tetrafluoroethane (R134a) to reduce pressure. Difluoromethane serves to, pentafluoroethane andtetrafluoroethane. R407C was developed as a replacement for the ozone depleting R22.


How Do You Know When You Need Air Conditioner Repair in Dallas / Fort Worth? Several things can impede the proper function of your air conditioning system. The accumulation of caked on grime and dirt on the condenser coil located outside can force the system to work harder and waste energy. A leak in the coils can result in insufficient refrigerant in the system. Other common culprits for malfunctioning air conditioning systems include a clogged A/C drain and faulty electric controls or sensors. The service professionals at Baker Brothers Plumbing & Air Conditioning will use the latest technology and tools to diagnose your air conditioning system’s problem and correct it quickly and cost-effectively. Our technicians will arrive at your home with fully stocked trucks with the tools and equipment they need to complete almost all jobs within one visit.
Air conditioner inverter Air door Air filter Air handler Air ionizer Air-mixing plenum Air purifier Air source heat pumps Automatic balancing valve Back boiler Barrier pipe Blast damper Boiler Centrifugal fan Ceramic heater Chiller Condensate pump Condenser Condensing boiler Convection heater Cooling tower Damper Dehumidifier Duct Economizer Electrostatic precipitator Evaporative cooler Evaporator Exhaust hood Expansion tank Fan coil unit Fan heater Fire damper Fireplace Fireplace insert Freeze stat Flue Freon Fume hood Furnace Furnace room Gas compressor Gas heater Gasoline heater Geothermal heat pump Grease duct Grille Ground-coupled heat exchanger Heat exchanger Heat pipe Heat pump Heating film Heating system High efficiency glandless circulating pump High-efficiency particulate air (HEPA) High pressure cut off switch Humidifier Infrared heater Inverter compressor Kerosene heater Louver Mechanical fan Mechanical room Oil heater Packaged terminal air conditioner Plenum space Pressurisation ductwork Process duct work Radiator Radiator reflector Recuperator Refrigerant Register Reversing valve Run-around coil Scroll compressor Solar chimney Solar-assisted heat pump Space heater Smoke exhaust ductwork Thermal expansion valve Thermal wheel Thermosiphon Thermostatic radiator valve Trickle vent Trombe wall Turning vanes Ultra-low particulate air (ULPA) Whole-house fan Windcatcher Wood-burning stove
Acosta Heating & Cooling is your one-stop-shop for all of your indoor comfort needs. We’ve been serving the Charlotte area for over 45 years, and our customers are always treated with respect and professionalism. But with so many air conditioning and heating companies out there, how are you supposed to choose? It all starts with how a company treats their customers. Here at Acosta Heating & Cooling, you’ll always be treated like family. From a quick furnace repair to comprehensive air conditioning service, Acosta will always deliver. See below for some reasons why we’re the best air conditioning and heating service company in Charlotte and surrounding areas:
Our NATE-certified technicians are always available, 24 hours a day and 365 days a year, to resolve emergency situations quickly and accurately.  Our team participates in factory-sponsored training updates, utilizes leading-edge diagnostic equipment, and follows strict installation and service procedures.  Every single Green Valley Cooling & Heating technician is clean air certified.  Rest assured, when you contact Green Valley Cooling & Heating, your call is answered by a skilled and experienced professional, who puts your best interests first.
We came home to a gas leak and our CO detector going off last Thursday (was very cold out)! After contacting Natl Fuel we proceeded to call Nerthlings for help! They arrived quickly, found the problem & worked with us to install our new furnace the next day. They were great to deal with & a huge help with the bad weather we were having at the time!
Our team is NATE-certified.  North American Technician Excellence represents the entire HVAC industry and is an independent, third-party, non-profit organization.  NATE-certified technicians are skilled professionals who have verified real working knowledge of HVAC systems through specialized exams.  Whether your heating or cooling system requires routine maintenance or complex repair, the NATE-certified team from Nerthling's Heating and Air Conditioning shows up on time, prepared to complete the job quickly and accurately, without unnecessary multiple house calls.  We work on all makes and models and offer affordable and convenient service plans to protect your equipment from wear and tear, and ensure like-new performance.
When it comes to furnace repair, Roswell and area residents can rely on us for fast and efficient repairs. Moncrief has continued to be a consistent provider of heating and cooling services in the Roswell and Marietta. We have worked hard to gain your respect by providing quality services and products, and delivering on our promise of total comfort for your home and family while providing energy and cost savings.
The compressor-based refrigerant systems are air-cooled, meaning they use air to exchange heat, in the same way as a car radiator or typical household air conditioner does. Such a system dehumidifies the air as it cools it. It collects water condensed from the cooled air and produces hot air which must be vented outside the cooled area; doing so transfers heat from the air in the cooled area to the outside air.
Before selecting the installation location of air conditioner, several main factors need to be considered. First of all, the direction of air flow from the indoor units should not fall on the place of rest or work area. Secondly, there should not be any obstacles on the way of the airflow that might prevent it from covering the space of the premises as much as possible. The outdoor unit must also be located in an open space, otherwise the heat from the house will not be effectively discharged outside and the productivity of the entire system will drop sharply. It is highly advisable to install the air conditioner units in easily accessible places, for further maintenance during operation.
When the thermostat calls for heat, 24 volts are sent to the electronic ignition control module, which energizes the furnace blower and other systems and sends 120 volts to the HSI. The HSI heats up to around 1,800°F to 2,500°F and glows red-hot. Then the gas valve opens, and the burner gas is ignited by the HSI. Once a proper flame is sensed by the flame sensor, the HSI turns off and stays off until the next heating cycle. In some furnaces, the HSI also serves as a flame sensor (called local sensing) instead of having a separate sensing rod in the burner flame (remote sensing).
Window unit air conditioners are installed in an open window. The interior air is cooled as a fan blows it over the evaporator. On the exterior the heat drawn from the interior is dissipated into the environment as a second fan blows outside air over the condenser. A large house or building may have several such units, allowing each room to be cooled separately.
You've probably noticed many appliances boasting an Energy Star Certification. What this means is that manufacturer voluntarily built the product to help reduce greenhouse gases and meet non-regulatory guidelines offered by the Environmental Protection Agency. To earn an Energy Star rating, a product or system must be tested by a third party that has been recognized by the EPA for meeting their testing qualifications.
Some systems include an "economizer mode", which is sometimes called a "free-cooling mode". When economizing, the control system will open (fully or partially) the outside air damper and close (fully or partially) the return air damper. This will cause fresh, outside air to be supplied to the system. When the outside air is cooler than the demanded cool air, this will allow the demand to be met without using the mechanical supply of cooling (typically chilled water or a direct expansion "DX" unit), thus saving energy. The control system can compare the temperature of the outside air vs. return air, or it can compare the enthalpy of the air, as is frequently done in climates where humidity is more of an issue. In both cases, the outside air must be less energetic than the return air for the system to enter the economizer mode.

Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
×