The fluid used for the heat transfer within a refrigeration system. The refrigerant absorbs heat at low temperature and pressure and transfers heat at high temperature and pressure. The refrigerant can be many materials, commonly fluorocarbon compounds, but also natural refrigerants such as ammonia, CO2, hydrocarbons as well as other compounds such as water and air.
Evaporative coolers tend to feel as if they are not working during times of high humidity, when there is not much dry air with which the coolers can work to make the air as cool as possible for dwelling occupants. Unlike other types of air conditioners, evaporative coolers rely on the outside air to be channeled through cooler pads that cool the air before it reaches the inside of a house through its air duct system; this cooled outside air must be allowed to push the warmer air within the house out through an exhaust opening such as an open door or window.[28] These coolers cost less and are mechanically simple to understand and maintain.
Heat pipe heat exchangers or run-around coils perform a similar function when humidity control is required. Two heat exchanger are placed in the air stream, one upstream of the cooling coil and the other downstream of the cooling coil. These heat exchangers are connected together with piping. A heat transfer fluid, whether it be water or refrigerant, is either pumped or gravity fed from one heat exchanger to the other. The heat exchanger down stream of the cooling coil (re-heat coil) cools the liquid medium inside the heat exchanger and heats the air passing over the heat exchanger. The cold liquid inside the heat exchanger is moved to the heat exchanger upstream of the cooling coil (pre-cool coil) where it pre-cools the air passing over the heat exchanger and warms the liquid passing through the heat exchanger. The affect of a heat pipe or run-around coil is to reduce the sensible heat capacity of the AC system. The latent capacity of the AC system increases if direct-expansion equipment is used or remains relatively constant if chilled water equipment is used. Since the sensible capacity of the AC system has been reduced, the system must run longer to meet the thermostat set point thereby removing more moisture.
The contactor (relay) and start/run capacitor(s) (see illustration below) fail most often and are inexpensive. So it’s a safe bet to buy and install those parts right away, especially if your air conditioning service unit is older than five years. The condenser fan motor can also fail, but it runs about $150 — hold off buying that unless you’re sure that’s the culprit.
The re-processing and upgrading of refrigerant by filtering, drying, distillation and sometimes chemical treatment of the recovered refrigerant. The re-processed substance will require laboratory analysis to verify that it meets a specific quality standard, normally that of new refrigerant. This normally involves processing “off-site” at a re-processing or a refrigerant manufacturing facility.

Clean air delivery rate is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 100 cfm (cubic feet per minute) and an efficiency of 50% has a CADR of 50 cfm. Along with CADR, filtration performance is very important when it comes to the air in our indoor environment. Filter performance depends on the size of the particle or fiber, the filter packing density and depth and also the air flow rate.[28]

Refrigerant Metering Device -- Every HVAC system has one of these, and heat pumps have two. They regulate the amount of refrigerant going through your air-conditioner. If it fails, either too much or too little refrigerant will course along the lines and either not perform well or will overwhelm the compressor and cause it to fail. A total failure of this component will result in a complete loss of operation.
An air conditioner cools and dehumidifies the air as is passes over a cold coil surface. The indoor coil is an air-to-liquid heat exchanger with rows of tubes that pass the liquid through the coil. Finned surfaces connected to these tubes increase the overall surface area of the cold surface thereby increasing the heat transfer characteristics between the air passing over the coil and liquid passing through the coil. The type of liquid used depends on the system selected. Direct-expansion (DX) equipment uses refrigerant as the liquid medium. Chilled-water (CW) can also be used as a liquid medium. When the required temperature of a chilled water system is near the freezing point of water, freeze protection is added in the form of glycols or salts. Regardless of the liquid medium used, the liquid is delivered to the cooling coil at a cold temperature.
We provide a full range of A/C, HVAC and heating repair services, providing a one-stop solution to all your temperature requirements. We specialize in residential applications, pride ourselves on tidy, discreet working and a commitment to giving every customer the very best service that we can. To find out more about us or schedule a visit, call us at (888) 462-0089.

Vredevoogd Heating & Cooling Grand Rapids MI routinely serves the areas of Grand Rapids, Wyoming, Lansing, Grandville, and Kalamazoo. We provide a comprehensive menu of HVAC services delivered by certified HVAC technicians who specialize in heating and cooling repair and installation. World-class customer service is a cornerstone of our business and we are committed to doing the job right the first time. We have a reputation for integrity and service excellence. By living up to our good name, we continue to build our customer base throughout the Michigan region and look forward to adding you to our service family. So if you are looking for a “heating & air company near me” in Grand Rapids, or a Furnace Repair Lansing, Furnace Repair Kalamazoo and more. Call today.
For complex commercial heating and cooling systems, you need an expert. When you run into malfunctions, it’s not a DIY job to fix it. At Air Blue Heating and Cooling Inc., we know how important your HVAC systems are to running your commercial facility. Anytime you need repairs, maintenance, or installations, contact our team of licensed professionals. With our extensive industry background, we provide the highest quality service for your systems. We always adhere to strict standards for procedures, training, and customer service. As a Carrier Factory Authorized Dealer, we meet rigid standards for customer service and technical expertise, so you know you’re getting the very best. Give us a call any time of the day for efficient, accurate, and long-lasting commercial HVAC services in Elk Grove Village, Addison, Bedford Park, Bensenville, Elmhurst, Chicagoland and the surrounding suburbs.

Heating Repair

×