We are service professionals! As licensed contractors and specialists in the field of heating and air conditioning, we have the tools, the equipment, and the experience to keep your equipment running smoothly all year long. If it is emergency service that you need we are available to assist you! To help reduce service emergencies, we offer service agreements to keep your comfort system running at peak performance.
Whether you’re looking to have a heat pump installed for the first time or think it’s time for an upgrade to your current system, Goettl Air Conditioning is the company to call. We offer a great lineup of Phoenix heat pumps and will make sure that the one we install in your home is the recommended match to your home’s dimensions and your family’s needs.

Once warm air inside your home blows across the indoor evaporator coil, its heat energy transfers to the refrigerant inside the coil. That transfer, in turn, “cools” the air. The refrigerant is pumped back to the compressor where the cycle begins again. The heat absorbed by the refrigerant is moved outside your home while cooled air is blown inside. Moisture that contributes to humidity is also condensed out of the air. Your cooling system is usually combined with your central heating system because they share the same ductwork for distributing conditioned air throughout your home.
"Reached out to them for a commercial place. 4 AC units broke down on the same day affecting our Business. Called all the so called big companies in town. They are all booked a month out. Tried Thumbtack per my friends recommendation. Right from when they reached out, they were fast, efficient & resolved all the issues & replaced a unit in no Time. Communicated all the repairs, warranty & certainly won our heats. Truly Exceptional!!"
Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants. A refrigerant is employed either in a heat pump system in which a compressor is used to drive thermodynamic refrigeration cycle, or in a free cooling system which uses pumps to circulate a cool refrigerant (typically water or a glycol mix).

At the first sign your HVAC system is not working properly, you should call us to schedule an appointment with one of our NATE-certified technicians. The longer you wait to have that strange noise or smell checked out, it could lead to higher repair bills or HVAC system failure. Don't wait until it is too late and you are without your heating or cooling equipment. Catching the problem early on could save you hundreds of dollars in repair bills.
Packaged terminal heat pumps (PTHP) are are similar to a window-mounted air conditioner. These units are typically installed in a sleeve passing through the outdoor wall of an apartment, hotel, school classroom, etc. PTHPs are completely self contained and require only an electrical connection in addition to the opening in the building shell. They use the outdoor air as the heat source in winter and as a heat sink in summer. They also can provide ventilation air. Flexibility and lower installed cost are the primary advantages of the PTHP. Disadvantages include in-room maintenance, higher operating cost, relatively short life, imprecise "on-off" temperature control, and they can be rather noisy.
Geothermal Heating and Cooling systems are unmatched in every way. This green alternative to temperature control is three times more efficient than conventional systems. Recognized by the US Environmental Protection Agency as the most environmentally-friendly option available today, installation of a geothermal HVAC system translates into a 50% reduction in heating costs, 30% reduction in cooling costs, and a 65% potential savings on hot water costs.  Sky Heating & Air Conditioning is now the largest WaterFurnace geothermal contractor west of Iowa. Our team of experienced professionals offer conscientious and skilled start-to-finish installation and service.  We specialize in outstanding geothermal HVAC systems, adding value and enjoyment to your home through sustainable solutions to year round temperature control. Contact Sky Heating & Air Conditioning for geothermal heat pump installation in Portland.
Concrete Blocks -- Concrete blocks are used in foundations and are often found in full basements. Insulating the spaces in the blocks is not the way to insulate them as the heat energy will travel along the concrete itself. The best way to insulate with concrete blocks is to use insulated concrete blocks, which have polystyrene incorporated into them.
Locally owned and family operated, M and M, Heating & Cooling, Plumbing & Electrical customizes solutions to perfectly fit your requirements and lifestyle. We specialize in a wide range of services including plumbing, water heating, indoor air quality, and residential and commercial temperature control. Our team of highly trained and certified technicians are fully licensed and insured, adhere to strict service procedures, and meet exacting standards of quality. Call on M and M, Heating & Cooling, Plumbing & Electrical at (720) 443-6119 for dedicated service throughout Longmont, CO & surrounding areas, and have confidence in a rewarding experience and long-term results. With over eighteen years of satisfied customers, we take great pride in a job done right.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.
How often you should clean your air ducts depends on your situation. If you or someone in the home has asthma or is acutely allergic to certain airborne materials or pollen, regular duct cleaning may be helpful. The Environmental Protection Agency doesn’t have an official position on the necessity of air duct cleaning unless the ducts have been contaminated by rodents, insects or mold, or you are aware of particles blowing out through the vents. The EPA recommends you have your air ducts cleaned on an as-needed basis. The National Air Duct Cleaners Association (NADCA) suggests having air ducts cleaned every three to five years.
This describes how much cooling the unit delivers for each watt of electricity. Efficiency is expressed as the seasonal energy-efficiency rating, or SEER. The minimum SEER for a split system central air conditioner allowed today is 14, so look for units with SEER ratings of 15 or greater. The higher the SEER, the more you can lower your energy costs.

You can install the greatest HVAC system ever built, but if your house is not insulated well, it's only going to end up costing you more money. Older homes may have fiberglass insulation that has broken down due to pests, moisture, or improper installation. Spray foam insulation can be damaged by careless repair or modification work or can be improperly installed. If your insulation in compromised, your attempts to save money and be comfortable will be in vain.
The compressor-based refrigerant systems are air-cooled, meaning they use air to exchange heat, in the same way as a car radiator or typical household air conditioner does. Such a system dehumidifies the air as it cools it. It collects water condensed from the cooled air and produces hot air which must be vented outside the cooled area; doing so transfers heat from the air in the cooled area to the outside air.
×