This single phase 13 SEER sweat air conditioning This single phase 13 SEER sweat air conditioning system is designed for residential and commercial applications and consists of the outdoor condenser indoor cased coil and 30 ft. line set. The compact micro-channel condenser is charged with R-410A refrigerant and has a top air discharge. The cased coil is filled ...  More + Product Details Close
Our fully trained and certified heating technicians have been repairing installing furnaces, heating systems and heat pumps in Smyrna and the Atlanta area since 1966.  We offer 24 hour emergency service for unexpected heating system break downs.  We can provide expert maintenance and repair on your current heating system or help you select a new, high-efficiency heating system from our wide range of furnaces.
A more efficient method of controlling humidity is to use the waste heat from the refrigeration cycle itself. Instead of rejecting the waste heat outdoors, the heat is directed inside when humidity control is required. One form of heat reclaim is called hot-gas reheat or “refrigerant desuperheating” where refrigerant is passed through a heat exchanger located downstream of the cooling coil. The hot high pressure vapor leaving the compressor passes through this heat exchanger prior to entering the condenser coil. This in turn heats the indoor air and again causes the AC system to run longer to meet the thermostat set point. Although more energy is used, this is much more efficient than turning on an electric heater. Another form of heat reclaim is called sub-cool reheat. This strategy takes the warm liquid refrigerant from the condenser and passes it through a heat exchanger located downstream of the cooling coil. Less heat is available using this method because the majority of the heat has already been rejected at the condenser. Since more energy is used to pump liquid (as opposed to a gas) through the heat exchanger it would appear that this method is less efficient than the hot-gas method, however, the liquid in the heat exchanger is sub-cooled in the cold supply air stream which increases the capacity of the air conditioner. Since more capacity is available, the AC units is able to meet the thermostat more quickly.
Cold aisle is a layout design for server racks and other computing equipment in a data centre. Cold aisle data center design involves lining up server racks in alternating rows with cold air intakes facing one way and hot air exhausts facing the other. The rows composed of rack fronts are called cold aisles. See Data Centre Aisle Containment for more information.

Heaters exist for various types of fuel, including solid fuels, liquids, and gases. Another type of heat source is electricity, normally heating ribbons composed of high resistance wire (see Nichrome). This principle is also used for baseboard heaters and portable heaters. Electrical heaters are often used as backup or supplemental heat for heat pump systems.
Sky Heating & Air Conditioning answers any comfort challenge with straightforward, satisfying solutions. We get rid of the need for labor-intensive renovation. We don’t tear down walls or ceilings, steal precious closet space for the installation of ductwork, or cause mess or damage. With the installation of a ductless HVAC system, we answer your temperature control requirements with wonderful simplicity.
Here at Baker Brothers, we know just how unbearable the heat in the DFW metroplex can be. That’s why we want your home’s air conditioning unit to be functioning properly. Whether you have a problem that you want to be solved now or just want to do preventative maintenance, we can help. Contact us today to schedule your HVAC service or repair in the Dallas & Fort Worth area!
Need 24-hour emergency furnace repair? We can provide that too. With our same-day service and live phone and online chat service available 24/7, we make your comfort our top priority. Heating and air conditioning should help you live a comfortable life, so let us help you make your home the most comfortable it has ever been. It’s easy, just grab your furnace repair coupon, then simply give us a call at 615-953-9885, chat or schedule an appointment with us online.
As a full-service heating contractor, we strongly encourage you to be vigilant with annual heating maintenance. Without proper maintenance, a heat pump, furnace or boiler might last only half as long as a well-maintained unit. Don’t tempt fate by skimping on annual service. We offer an economical, yet comprehensive maintenance agreement that we call our Cool Care Service Agreement. With our maintenance agreement you’ll receive:
We provide a full range of A/C, HVAC and heating repair services, providing a one-stop solution to all your temperature requirements. We specialize in residential applications, pride ourselves on tidy, discreet working and a commitment to giving every customer the very best service that we can. To find out more about us or schedule a visit, call us at (888) 462-0089.
The chill of winter can be a scary thought when your furnace needs repair. When the furnace in your home goes on the fritz, you need it fixed right away to keep your family safe and comfortable. Every BGE HOME technician is licensed and adheres to a stringent in-house certification program that guarantees their knowledge, affirms their commitment to the customer, and ensures excellence in completing every furnace repair with the highest level of quality.
Dunes Heating And Air Conditioning is HVAC Contractor providing the best possible Heating and Air Conditioning Repair, maintenance and installation for your home or business in Mount Pleasant, Charleston and Isle of Palms South Carolina. You can count on us to provide you with a system and solution that fits your unique needs and since we've installed many systems in this area, we've earned a reputation for doing the job right the first time.

Many disconnect blocks contain two cartridge fuses. Check them before you proceed with repairs (Photo 3). A blown fuse is a sign of a failing part inside the condensing unit. So don’t just replace it and think you’ve solved the problem. Instead, replace the parts we show here. Then install new fuses and fire up the unit. If it blows again, call a pro—you’ve got more serious issues.
This describes how much cooling the unit delivers for each watt of electricity. Efficiency is expressed as the seasonal energy-efficiency rating, or SEER. The minimum SEER for a split system central air conditioner allowed today is 14, so look for units with SEER ratings of 15 or greater. The higher the SEER, the more you can lower your energy costs.
Refrigerant Metering Device -- Every HVAC system has one of these, and heat pumps have two. They regulate the amount of refrigerant going through your air-conditioner. If it fails, either too much or too little refrigerant will course along the lines and either not perform well or will overwhelm the compressor and cause it to fail. A total failure of this component will result in a complete loss of operation.
Humidity is becoming more of a concern to building operators and owners. High indoor humidity leads to mold and mildew growth inside the building. The are several methods of controlling indoor humidity. The simplest (and most expensive) method is to connect a humidistat to an electric heater. When the humidity inside the building rises above the humidistat set point, the heater is turned on. The additional heat causes the air conditioning system to run longer and remove more moisture.
×