A dehumidifier is an air-conditioner-like device that controls the humidity of a room or building. It is often employed in basements which have a higher relative humidity because of their lower temperature (and propensity for damp floors and walls). In food retailing establishments, large open chiller cabinets are highly effective at dehumidifying the internal air. Conversely, a humidifier increases the humidity of a building.

This single phase 13 SEER sweat air conditioning This single phase 13 SEER sweat air conditioning system is designed for residential and commercial applications and consists of the outdoor condenser indoor cased coil and 30 ft. line set. The compact micro-channel condenser is charged with R-410A refrigerant and has a top air discharge. The cased coil is filled ...  More + Product Details Close


A heat pump is an air conditioner in which the refrigeration cycle can be reversed, producing heating instead of cooling in the indoor environment. They are also commonly referred to as a "reverse cycle air conditioner". The heat pump is significantly more energy efficient than electric resistance heating. Some homeowners elect to have a heat pump system installed as a feature of a central air conditioner. When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator, and discharges cold air (colder than the ambient outdoor air).

As the name implies, a window air conditioner is typically installed in a window or custom opening in a wall. The Window AC can only cool small areas and are not intended to provide cooling to multiple rooms or zones. These air conditioners are manufactured as cool only or can provide both cooling and heating. An optional damper in the unit can provide fresh outdoor air if necessary.
In the case of direct expansion equipment, the air passing over the indoor cooling coil heats the cold liquid refrigerant. Heating the refrigerant causes boiling and transforms the refrigerant from a cold liquid to a warm gas. This warm gas (or vapor) is pumped from the cooling coil to the compressor through a copper tube (suction line to the compressor) where the warm gas is compressed. In some cases, an accumulator is placed between the cooling coil and the compressor to capture unused liquid refrigerant and ensures that only vapor enters the compressor. The compression process increases the pressure of the refrigerant vapor and significantly increases the temperature of the vapor. The compressor pumps the vapor through another heat exchanger (outdoor condenser) where heat is rejected and the hot gas is condensed to a warm high pressure liquid. This warm high pressure liquid is pumped through a smaller copper tube (liquid line) to a filter (or filter/dryer) and then on to an expansion device where the high pressure liquid is reduced to a cold, low pressure liquid. The cold liquid enters the indoor cooling coil and the process repeats.
Nytech Heating and Cooling, is a Colorado CO Heating, Cooling, Air Conditioning, Heat Pump, Ductless Mini-Split, Furnace repair, service, replacement and maintenance Company located in Douglas County. Nytech Heating and Cooling employs only the best technician for air conditioner repair and furnace repair, as well as all air conditioner replacement, furnace replacement and boiler replacement in Castle Rock CO, Castle Pines CO, Centennial CO, Elbert CO, Elizabeth CO, Englewood CO, Franktown CO, Greenwood Village CO, Highland Ranch CO, Larkspur CO, Littleton CO, Louviers CO, Lone Tree CO, Parker CO, and Sedalia CO. So when you ask to find "A good heating and air conditioning repair or service company near me," you've come to the right place. To set-up a repair service estimate or replacement estimate, call 303-663-6840. Nytech Heating and Cooling services all furnace, AC, humidifier, filter, thermostat and water heater brands including Carrier, Bryant, Payne, Trane, Lennox, Rheem, Ruud, Amana, Daikin, Mitsubishi, Fujitsu, Crown, Frigidaire, Gibson, Goodman, Maytag, Weil McLain, A O Smith, American Standard, General, Aprilaire, Honeywell, and White Rodgers.

Need your air conditioning repaired today? Let Dunes Heating and Air Conditioning LLC.  same-day air conditioning repair service come to the rescue. Our air conditioning repair, maintenance and installation technicians and contractors are some of the most highly skilled AC repair technicians in the area. So whether you need your commercial air conditioner repaired or your home air conditioning system replaced, let our team of factory trained and certified home central air conditioning repair technicians be there for you and your family!

If you have a heating or cooling emergency, call Vredevoogd Heating & Cooling Grand Rapids MI, Furnace Repair Lansing, Furnace Repair Kalamazoo and more at 616-828-5411. When you call you speak directly with one of our service representatives about the problem you are experiencing and schedule a service appointment. Naturally, we prioritize emergencies so you can count on us when your heating or cooling systems fail. After regular business hours, you can reach our customer service staff who will report your problem to on-call technicians. You can expect to hear back from a certified tech within 15 minutes of your call. Your heating and cooling emergency is important to us. We will visit your home ASAP to provide you with the superior service you’d expect from a Furnace Repair, Air Conditioning, AC Repair & HVAC leader like Vredevoogd Heating & Cooling Grand Rapids, AC Repair Lansing, AC Repair Kalamazoo.


No one wants to be stuck in the dead of summer with a broken air conditioner, or in the cold of winter with a broken furnace or boiler. That’s why we’re available any time of day to make your emergency heating and air conditioning repair and get your system up and running as quickly as possible. We’ll show up on time, in uniform and ready to make your HVAC repair right the first time.
Hospital operating theatres, in which air is filtered to high levels to reduce infection risk and the humidity controlled to limit patient dehydration. Although temperatures are often in the comfort range, some specialist procedures, such as open heart surgery, require low temperatures (about 18 °C, 64 °F) and others, such as neonatal, relatively high temperatures (about 28 °C, 82 °F).
In the event of an emergency with your residential heating and cooling system, we understand that you simply cannot wait! At R.S. Andrews, we take your comfort and well-being seriously and are proud to offer our emergency HVAC repair at any hour, on any day—including weekends! We provide only the highest quality services to ensure your needs are met!
In order to make your everyday life easier and more enjoyable, Sky Heating & Air Conditioning specializes in state-of-the-art heating and cooling technology, partnering with Trane, Mitsubishi, and Waterfurnace.  We bring you HVAC solutions that represent the best the industry has to offer, ensuring long-term performance and satisfaction.  Whether you’re looking for the design/build of a new system, replacement, or hoping to cut costs and enhance convenience, we answer with proven products.  Our qualified HVAC technicians help you determine the ideal solution for your exact requirements, and make sure you’re happy with every step of the process.  From ductless HVAC to geothermal heating and cooling systems, we offer a wide selection of options and comprehensive services to answer any type of challenge.  Call on Sky Heating & Air Conditioning and let us exceed your expectations today!
Split-system central air conditioner – for this type of system, there are two separate cabinets. One is located outside in a metal cabinet and houses the condenser and compressor.  The second cabinet is on the inside of the house and contains the evaporator.  Typically, the indoor cabinet contains a furnace or part of a heat pump, which has the evaporator coils installed in the main supply duct of the heat pump or furnace.  This system is great for anyone who already has a furnace but no air conditioner.  It offers the most affordable option for their needs.

An improperly maintained heating and air conditioning is an inefficient heating and air conditioning system. That’s why we provide appointments for annual inspections with our licensed technicians. It’s our goal to make sure that your home is as comfortable and energy-efficient as possible. For inspections, repairs, and service, contact BGE HOME for quality service.


Need 24-hour emergency furnace repair? We can provide that too. With our same-day service and live phone and online chat service available 24/7, we make your comfort our top priority. Heating and air conditioning should help you live a comfortable life, so let us help you make your home the most comfortable it has ever been. It’s easy, just grab your furnace repair coupon, then simply give us a call at 615-953-9885, chat or schedule an appointment with us online.
Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.
In very dry climates, evaporative coolers, sometimes referred to as swamp coolers or desert coolers, are popular for improving coolness during hot weather. An evaporative cooler is a device that draws outside air through a wet pad, such as a large sponge soaked with water. The sensible heat of the incoming air, as measured by a dry bulb thermometer, is reduced. The temperature of the incoming air is reduced, but it is also more humid, so the total heat (sensible heat plus latent heat) is unchanged. Some of the sensible heat of the entering air is converted to latent heat by the evaporation of water in the wet cooler pads. If the entering air is dry enough, the results can be quite substantial.
Heat pipe heat exchangers or run-around coils perform a similar function when humidity control is required. Two heat exchanger are placed in the air stream, one upstream of the cooling coil and the other downstream of the cooling coil. These heat exchangers are connected together with piping. A heat transfer fluid, whether it be water or refrigerant, is either pumped or gravity fed from one heat exchanger to the other. The heat exchanger down stream of the cooling coil (re-heat coil) cools the liquid medium inside the heat exchanger and heats the air passing over the heat exchanger. The cold liquid inside the heat exchanger is moved to the heat exchanger upstream of the cooling coil (pre-cool coil) where it pre-cools the air passing over the heat exchanger and warms the liquid passing through the heat exchanger. The affect of a heat pipe or run-around coil is to reduce the sensible heat capacity of the AC system. The latent capacity of the AC system increases if direct-expansion equipment is used or remains relatively constant if chilled water equipment is used. Since the sensible capacity of the AC system has been reduced, the system must run longer to meet the thermostat set point thereby removing more moisture.
Furnace Circuit Board -- The furnace circuit board controls a variety of functions. It not only handles the regular operation of the furnace, it also monitors the furnace's various safety circuits. Over time, vibrations from the furnace can weaken solder point and cause them to separate. Dirt and debris can cause short-circuits that damage the board. Failure of the circuit board can cause a variety of effects ranging from the fan not turning on to the complete shutdown of the furnace.
×