Refrigerant Metering Device -- Every HVAC system has one of these, and heat pumps have two. They regulate the amount of refrigerant going through your air-conditioner. If it fails, either too much or too little refrigerant will course along the lines and either not perform well or will overwhelm the compressor and cause it to fail. A total failure of this component will result in a complete loss of operation.
A split system is a combination of an indoor air handling unit and an outdoor condensing unit. The indoor air handling unit contains a supply air fan and an air-to-refrigerant heat exchanger (or cooling coil), and the expansion device. The outdoor condensing unit consists of a compressor and a condenser coil. Split-systems are typically found in residential or small commercial buildings. These systems have the highest energy efficiency rating (EER) of all the available AC systems. Manufacturers are required to take the EER rating a step further and provide a seasonal energy efficiency rating (SEER) for use by consumers. SEER ratings vary widely and range from 10 to 20. The higher the SEER rating, the more efficient the AC system operates. If heating is required, an alternate method of heating the interior of the building must be used, usually in the form of electric or gas heating.
Heat pipe heat exchangers or run-around coils perform a similar function when humidity control is required. Two heat exchanger are placed in the air stream, one upstream of the cooling coil and the other downstream of the cooling coil. These heat exchangers are connected together with piping. A heat transfer fluid, whether it be water or refrigerant, is either pumped or gravity fed from one heat exchanger to the other. The heat exchanger down stream of the cooling coil (re-heat coil) cools the liquid medium inside the heat exchanger and heats the air passing over the heat exchanger. The cold liquid inside the heat exchanger is moved to the heat exchanger upstream of the cooling coil (pre-cool coil) where it pre-cools the air passing over the heat exchanger and warms the liquid passing through the heat exchanger. The affect of a heat pipe or run-around coil is to reduce the sensible heat capacity of the AC system. The latent capacity of the AC system increases if direct-expansion equipment is used or remains relatively constant if chilled water equipment is used. Since the sensible capacity of the AC system has been reduced, the system must run longer to meet the thermostat set point thereby removing more moisture.

Whether you’re looking to have a heat pump installed for the first time or think it’s time for an upgrade to your current system, Goettl Air Conditioning is the company to call. We offer a great lineup of Phoenix heat pumps and will make sure that the one we install in your home is the recommended match to your home’s dimensions and your family’s needs.
Some of the most common problems that require gas furnace repair include malfunctioning thermostats, frequent cycling, blowers that continuously run, excessive noise, general lack of maintenance, dirty filters and electric ignition or pilot control problems. Repair Clinic can show you how to fix your furnace and save you money on the parts and repair. Safety first! Be sure to consult an HVAC pro if you’re not confident making furnace repairs.
Hi reader in the U.S., it seems you use Wikipedia a lot; that's great! It's a little awkward to ask, but this Monday we need your help. If you have already donated, we sincerely thank you. We’re not salespeople, but we depend on donations averaging $16.36 and fewer than 1% of readers give. If you donate just $2.50, the price of your coffee this Monday, Wikipedia could keep thriving. Thank you.

A more efficient method of controlling humidity is to use the waste heat from the refrigeration cycle itself. Instead of rejecting the waste heat outdoors, the heat is directed inside when humidity control is required. One form of heat reclaim is called hot-gas reheat or “refrigerant desuperheating” where refrigerant is passed through a heat exchanger located downstream of the cooling coil. The hot high pressure vapor leaving the compressor passes through this heat exchanger prior to entering the condenser coil. This in turn heats the indoor air and again causes the AC system to run longer to meet the thermostat set point. Although more energy is used, this is much more efficient than turning on an electric heater. Another form of heat reclaim is called sub-cool reheat. This strategy takes the warm liquid refrigerant from the condenser and passes it through a heat exchanger located downstream of the cooling coil. Less heat is available using this method because the majority of the heat has already been rejected at the condenser. Since more energy is used to pump liquid (as opposed to a gas) through the heat exchanger it would appear that this method is less efficient than the hot-gas method, however, the liquid in the heat exchanger is sub-cooled in the cold supply air stream which increases the capacity of the air conditioner. Since more capacity is available, the AC units is able to meet the thermostat more quickly.

Air Handling Unit (AHU): a device used to condition and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blower, heating or cooling elements, filter racks or chambers, sound attenuators, and dampers. Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU.
Without proper ventilation, carbon monoxide can be lethal at concentrations of 1000 ppm (0.1%). However, at several hundred ppm, carbon monoxide exposure induces headaches, fatigue, nausea, and vomiting. Carbon monoxide binds with hemoglobin in the blood, forming carboxyhemoglobin, reducing the blood's ability to transport oxygen. The primary health concerns associated with carbon monoxide exposure are its cardiovascular and neurobehavioral effects. Carbon monoxide can cause atherosclerosis (the hardening of arteries) and can also trigger heart attacks. Neurologically, carbon monoxide exposure reduces hand to eye coordination, vigilance, and continuous performance. It can also affect time discrimination.[15]
In 1992, a non-governmental organization, Greenpeace, was spurred by corporate executive policies and requested that a European lab find substitute refrigerants. This led to two alternatives, one a blend of propane (R290) and isobutane (R600a), and one of pure isobutane.[18][22] Industry resisted change in Europe until 1993, and in the U.S. until 2011, despite some supportive steps in 2004 and 2008 (see Refrigerant Development above).[27][67]
When our Denver heating company provides you with maintenance checks before the cold of winter sets in, you will be saving money in several different ways. One of the benefits of a maintenance plan is our technicians will be less likely to have to make repairs throughout the year as long as the system is properly maintained. Our Denver heating company will have your system running at its most efficient, helping to reduce your utility bills each month. An added benefit of a more efficiently running system is the positive environmental effect that it will have.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.

Here at Brothers Plumbing, Heating, and Electric, we have a Home Care Club that provides members with many benefits. These benefits include: 2 year warranty on all work (drain work is excluded), transferable club membership, no “show up” fees, priority service, 10% discount on repairs, quarterly newsletters, carefree scheduling (we will contact you and remind you when you need service), 2 free furnace/air conditioner filter changes, exclusive coupons, quarterly drawings, 4 on-going safety checks, and a 100% satisfaction guarantee. So if you’d like to join our Home Care Club, then give us a call or click here today.
Our professional AC Repair technicians are certified and well trained to handle all of your AC repair and air conditioning needs including: Central Air Conditioner. Split System. Ductless Mini Split Air Conditioner. Through The Wall Air Conditioner. Indoor Packaged Units and Rooftop Packaged Units. For Same Day Air Conditioner Repair And Installation Service Call 215.725.6111
"I had several fits and starts trying to get an A/C HVAC system installed in my home in Boulder. I talked to multiple local contractors, and did a great deal of research on what people are paying for such work in various parts of the country. There is a huge disconnect between the Boulder market, and the rest of the country, based on nothing more than local contractors grossly overcharging gullible, very affluent, customers. This leaves the average Joe or Jane to either pay up, or fend for themselves. Some of the locals seemed promising, only to hit us with outrageously overpriced bids. I'm not talking about a 20% "local vig"--I'm talking 2-3 times national rates! Some never showed up, some came to look at the job, then never even followed up, like they just couldn't be bothered. Steels Bros, in complete contrast to these difficulties, showed up when they said they would, did what they said they would do, and did it all for a fair price. At each step, they were concerned that they were earning my satisfaction with their work. I am a huge believer in providing the best customer service possible in my own work, and Steele Bros showed the same commitment. I would not hesitate to recommend them to anyone that wants a big job done right, at a fair price. "

Heat pipe heat exchangers or run-around coils perform a similar function when humidity control is required. Two heat exchanger are placed in the air stream, one upstream of the cooling coil and the other downstream of the cooling coil. These heat exchangers are connected together with piping. A heat transfer fluid, whether it be water or refrigerant, is either pumped or gravity fed from one heat exchanger to the other. The heat exchanger down stream of the cooling coil (re-heat coil) cools the liquid medium inside the heat exchanger and heats the air passing over the heat exchanger. The cold liquid inside the heat exchanger is moved to the heat exchanger upstream of the cooling coil (pre-cool coil) where it pre-cools the air passing over the heat exchanger and warms the liquid passing through the heat exchanger. The affect of a heat pipe or run-around coil is to reduce the sensible heat capacity of the AC system. The latent capacity of the AC system increases if direct-expansion equipment is used or remains relatively constant if chilled water equipment is used. Since the sensible capacity of the AC system has been reduced, the system must run longer to meet the thermostat set point thereby removing more moisture.


A mini-split system typically supplies air conditioned and heated air to a single or a few rooms of a building.[38] Multi-zone systems are a common application of ductless systems and allow up to 8 rooms (zones) to be conditioned from a single outdoor unit. Multi-zone systems typically offer a variety of indoor unit styles including wall-mounted, ceiling-mounted, ceiling recessed, and horizontal ducted. Mini-split systems typically produce 9,000 to 36,000 Btu (9,500–38,000 kJ) per hour of cooling. Multi-zone systems provide extended cooling and heating capacity up to 60,000 Btu's.
Consumer Reports is an independent, non-profit organization dedicated to helping consumers. We make it easy to buy the right product from a variety of retailers. Clicking a retailer link will take you to that retailer’s website to shop. When you shop through retailer links on our site, we may earn an affiliate commission – 100% of the fees we collect are used to support our mission. Learn more. Our service is unbiased: retailers can’t influence placement. All prices are subject to change.

We are service professionals! As licensed contractors and specialists in the field of heating and air-conditioning, we have the tools, the equipment, and the experience to keep your equipment running smoothly all year long. If it is emergency service that you need, twenty-four hours a day, seven days a week, we are available to assist you! To help reduce service emergencies, we offer service agreements to keep your comfort system running at peak performance.

"LIFESAVER! Came right out to our home to save us from the heat. I called around 11 and they sent someone by the afternoon 1:30. Carlos fixed our AC on the spot! Very professional and knew what the issues were and fixed them all as fast as possible! Otherwise we would all be toast in this Texas Summer HEat. Thank you Carlos with Ruben's AC! Excellent service"

Roof-mounted systems have the heating and cooling systems in one cabinet. Sometimes called "gas packs" (if the heater uses natural gas), they typically cost less than a comparable split system. In dry regions, most homes originally had "swamp-coolers" installed. When replacing them with HVAC systems, it's often cheaper to use existing mounts and ducting.


Furnace Circuit Board -- The furnace circuit board controls a variety of functions. It not only handles the regular operation of the furnace, it also monitors the furnace's various safety circuits. Over time, vibrations from the furnace can weaken solder point and cause them to separate. Dirt and debris can cause short-circuits that damage the board. Failure of the circuit board can cause a variety of effects ranging from the fan not turning on to the complete shutdown of the furnace.
×