In variable climates, the system may include a reversing valve that switches from heating in winter to cooling in summer. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a facility to be heated and cooled by a single piece of equipment by the same means, and with the same hardware.
Our expertise in boiler, heat pump, furnace and all types of heating repair and installation includes all makes and models. If your equipment is old, new, requires maintenance or needs a major repair – HVAC Philly your trusted Heater repair company providing quality repairs & services including: Gas heating. Electric Heat Pumps. Furnace. Boiler. Hot water and Steam.
Whether you might be in need of a commercial or residential heating or even air conditioners specialist, Heating Repair Moorpark stands all set to help. Heating Repair Moorpark continues to develop a name for unparalleled client services and enthusiasm. We are continuously evaluating the indoor comfort problems present in houses across Moorpark. Our studies have shown that regardless of products brand, most issues with heating and cooling systems can be eliminated by appropriate equipment application, installing and disciplined servicing methods.
The fluid used for the heat transfer within a refrigeration system. The refrigerant absorbs heat at low temperature and pressure and transfers heat at high temperature and pressure. The refrigerant can be many materials, commonly fluorocarbon compounds, but also natural refrigerants such as ammonia, CO2, hydrocarbons as well as other compounds such as water and air.
Our goal is to make you more comfortable in your home. When your furnace, central air conditioner, heat pump or boiler stops working and you need service, call the professionals at BGE HOME. Heating and cooling system breakdowns occur at the most inconvenient times, so rely on our certified, skilled technicians to make the repair quickly and correctly the first time.

Air conditioning can also be provided by a process called free cooling which uses pumps to circulate a coolant (typically water or a glycol mix) from a cold source, which in turn acts as a heat sink for the energy that is removed from the cooled space. Common storage media are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter boreholes, equipped with heat exchanger. Some systems with small storage capacity are hybrid systems, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added because the temperature of the storage gradually increases during the cooling season, thereby declining its effectiveness.
Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]
In the case of direct expansion equipment, the air passing over the indoor cooling coil heats the cold liquid refrigerant. Heating the refrigerant causes boiling and transforms the refrigerant from a cold liquid to a warm gas. This warm gas (or vapor) is pumped from the cooling coil to the compressor through a copper tube (suction line to the compressor) where the warm gas is compressed. In some cases, an accumulator is placed between the cooling coil and the compressor to capture unused liquid refrigerant and ensures that only vapor enters the compressor. The compression process increases the pressure of the refrigerant vapor and significantly increases the temperature of the vapor. The compressor pumps the vapor through another heat exchanger (outdoor condenser) where heat is rejected and the hot gas is condensed to a warm high pressure liquid. This warm high pressure liquid is pumped through a smaller copper tube (liquid line) to a filter (or filter/dryer) and then on to an expansion device where the high pressure liquid is reduced to a cold, low pressure liquid. The cold liquid enters the indoor cooling coil and the process repeats.
Bonney’s NATE certified technicians will troubleshoot and repair your furnace for safe and reliable operation. Our technicians use state of the art tools including video inspection cameras and exhaust gas analyzers to perform thorough, comprehensive diagnostics when equipment is broken. Furthermore, we arrive in a “warehouse on wheels” stocked with many parts to get your furnace repaired as quickly as possible.  For an unexpected heater repair Bonney offers financing to make your comfort affordable.
As this liquid passes through the indoor cooling coil on the inside of the heat exchanger, two things happen to the air that passes over the coil’s surface on the outside of the heat exchanger. The air’s temperature is lowered (sensible cooling) and moisture in the air is removed (latent cooling) if the indoor air dew point is higher than the temperature of the coil’s surface. The total cooling (capacity) of an AC system is the sum of the sensible and latent cooling. Many factors influence the cooling capacity of a DX air conditioner. Total cooling is inversely proportional to outdoor temperature. As the outdoor temperature increases the total capacity is reduced. Air flow over the indoor cooling coil also affects the coil’s capacity and is directly proportional to the total capacity of an AC system. As air flow increases, the total capacity also increases. At higher air flow rates the latent capacity of the cooling coil is reduced. Indoor temperature and humidity also affect the total capacity of the AC system. As indoor temperatures increase, the sensible capacity also increases. Similarly, as indoor relative humidity increases the latent capacity of the AC system increases. Manufacturers of AC equipment typically provide a “performance map” of specific equipment to show how total, sensible, and latent capacity change with changing indoor and outdoor temperatures and humidity. Power consumption and energy efficiency are also provided in these charts.

Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs while the fan is slowed as much as possible[citation needed] to reduce the evaporator temperature and therefore condense more water. When the temperature falls below a threshold, both the fan and compressor are shut off to mitigate further temperature drops;[clarification needed] this prevents moisture on the evaporator from being blown back into the room.[citation needed] When the temperature rises again,[clarification needed] the compressor restarts and the fan returns to low speed.
It's quite possible that you need a new HVAC unit, but we can't tell for certain. We will need to do a complete inspection of the property and conditions the unit is in. Because of the multiple maintenance aspects regarding HVAC units that could and will prevent the unit's proper functions. We are the experts in diagnostics and repairs. If your HVAC unit is at all salvageable... before we are done we'll make sure that it operates in peak condition.
Packaged central air conditioner – the name is a good indicator of what to expect from a packaged central air conditioner. The evaporator, compressor, and condenser are all installed in one cabinet.  This cabinet is typically placed on a roof or a concrete slab near the house’s foundation.  Packaged ones normally include electric heating coils or a natural gas furnace, which eliminates the need for a separate furnace inside.
Electronically Commutated (EC) fans use brushless DC motors which include in-built electronics to convert the AC supply to DC without the need for a separate DC supply. EC fans provide a more efficient (up to 30%) means of airflow through Precision Air Conditioning (PAC) units with the additional benefit of variable speed control via an output signal from the unit controller. Also see EC Fan upgrades.
Engineers have pointed out some areas where efficiency of the existing hardware could be improved. For example, the fan blades used to move the air are usually stamped from sheet metal, an economical method of manufacture, but as a result they are not aerodynamically efficient. A well-designed blade could reduce electrical power required to move the air by a third.[26]
Fresh-Aire UV is an innovation leader in the field of indoor air quality. Our award-winning UV light and carbon products fight mold, bacteria, viruses and odors in commercial and residential HVACR systems. Our products include Blue-Tube UV®, the world’s most popular germicidal UV light, the revolutionary APCO® PCO/carbon whole-house air purifier, and Mini UV the first UV light system designed specifically for mini-split AC systems.
Attic Fan Installation Bathroom Fan Repair Ceiling Fan Installation Ceiling Fan Repair Electric Wall Heater Installation Electrical Panel Installation Electrical Panel Repair Electrical Panel Upgrade Electrical Wiring Installation Electrical Wiring Upgrade Exhaust Fan Installation Holiday Lighting Installation LED Interior Light Conversion Light Fixture Installation Light Fixture Repair Light Fixture Replacement Light Switch Installation Outlet Installation Outlet Repair Spa Wiring Installation
Some of these components can be repaired or replaced by the homeowner, such as filters, fuses, and clogged up drain lines. Coils, compressors and the other components are best left to a professional. In some cases, you may have a system that is so old that parts are no longer available or else they aren't up to code. In this case you will have to consider replacing the entire system.

Packaged terminal heat pumps (PTHP) are are similar to a window-mounted air conditioner. These units are typically installed in a sleeve passing through the outdoor wall of an apartment, hotel, school classroom, etc. PTHPs are completely self contained and require only an electrical connection in addition to the opening in the building shell. They use the outdoor air as the heat source in winter and as a heat sink in summer. They also can provide ventilation air. Flexibility and lower installed cost are the primary advantages of the PTHP. Disadvantages include in-room maintenance, higher operating cost, relatively short life, imprecise "on-off" temperature control, and they can be rather noisy.

Before selecting the installation location of air conditioner, several main factors need to be considered. First of all, the direction of air flow from the indoor units should not fall on the place of rest or work area. Secondly, there should not be any obstacles on the way of the airflow that might prevent it from covering the space of the premises as much as possible. The outdoor unit must also be located in an open space, otherwise the heat from the house will not be effectively discharged outside and the productivity of the entire system will drop sharply. It is highly advisable to install the air conditioner units in easily accessible places, for further maintenance during operation.


About us: Vredevoogd Heating & Cooling has been in business since 1964. As a financially stable company known for its reliable expertise and first-rate customer care, Vredevoogd Heating & Cooling is a company you can trust. Moreover, when you do business with a stable business like Vredevoogd Heating & Cooling, you have the peace of mind of knowing that your warranties are solidly backed by a company that intends to remain in business for another 50+ years and beyond. Don’t trust your essential home systems and investment to any fly-by-night company. Our best practices ensure that we will be here to meet our customer’s HVAC needs for decades to come. Vredevoogd Heating & Cooling founder Dennis Vredevoogd set the high standards by which the company continues to pride itself for. Today, the company continues to be family owned and operated by the founder’s sons, Michael and Thomas, who are committed to maintaining the company’s high standards and complementing them with the innovative technical know-how needed to service today’s advanced HVAC systems.
Having the most energy-efficient system ever built won't matter much if it's not maintained. Lack of maintenance is the number one killer of HVAC systems. Before each cooling season, it's recommended that your system get a professional tune-up. However, there are things you can do in the meantime to make sure your system runs efficiently throughout the year.
Keep your home comfortable all year round with Keep your home comfortable all year round with this high quality and efficient 14 SEER central heating and cooling heat pump system. This system is ideal for new or replacement residential or commercial applications and consists of the outdoor condenser indoor air handler with evaporator coil heat strip and 30 ...  More + Product Details Close
Since 1968, Eanes Heating and Air Conditioning has been providing high-quality heating and cooling products and services across the Piedmont Triad Area of North Carolina. Centrally located in High Point, NC, the Eanes service area covers the cities of Greensboro, Winston Salem, Kernersville, Thomasville, Lexington, Randleman, and all points in between. As a local, family-owned business, Eanes takes great pride in providing trusted advice and straight talk service on HVAC installation, repair, and maintenance for both commercial and residential applications. With a commitment to service and integrity, the company is driven by a set of values that have contributed to its continued growth and success.
Ventilating or ventilation (the V in HVAC) is the process of exchanging or replacing air in any space to provide high indoor air quality which involves temperature control, oxygen replenishment, and removal of moisture, odors, smoke, heat, dust, airborne bacteria, carbon dioxide, and other gases. Ventilation removes unpleasant smells and excessive moisture, introduces outside air, keeps interior building air circulating, and prevents stagnation of the interior air.
Within the construction sector, it is the job of the building services engineer to design and oversee the installation and maintenance of the essential services such as gas, electricity, water, heating and lighting, as well as many others. These all help to make buildings comfortable and healthy places to live and work in. Building Services is part of a sector that has over 51,000 businesses and employs represents 2%-3% of the GDP.

In 1820, English scientist and inventor Michael Faraday discovered that compressing and liquefying ammonia could chill air when the liquefied ammonia was allowed to evaporate. In 1842, Florida physician John Gorrie used compressor technology to create ice, which he used to cool air for his patients in his hospital in Apalachicola, Florida. He hoped to eventually use his ice-making machine to regulate the temperature of buildings. He even envisioned centralized air conditioning that could cool entire cities. Though his prototype leaked and performed irregularly, Gorrie was granted a patent in 1851 for his ice-making machine. Though his process improved the artificial production of ice, his hopes for its success vanished soon afterwards when his chief financial backer died and Gorrie did not get the money he needed to develop the machine. According to his biographer, Vivian M. Sherlock, he blamed the "Ice King", Frederic Tudor, for his failure, suspecting that Tudor had launched a smear campaign against his invention. Dr. Gorrie died impoverished in 1855, and the dream of commonplace air conditioning went away for 50 years.[citation needed]


The compressor-based refrigerant systems are air-cooled, meaning they use air to exchange heat, in the same way as a car radiator or typical household air conditioner does. Such a system dehumidifies the air as it cools it. It collects water condensed from the cooled air and produces hot air which must be vented outside the cooled area; doing so transfers heat from the air in the cooled area to the outside air.
×