How often you should clean your air ducts depends on your situation. If you or someone in the home has asthma or is acutely allergic to certain airborne materials or pollen, regular duct cleaning may be helpful. The Environmental Protection Agency doesn’t have an official position on the necessity of air duct cleaning unless the ducts have been contaminated by rodents, insects or mold, or you are aware of particles blowing out through the vents. The EPA recommends you have your air ducts cleaned on an as-needed basis. The National Air Duct Cleaners Association (NADCA) suggests having air ducts cleaned every three to five years.
A true central air-conditioning system uses ducts to distribute cooled air throughout the house. In a “split system,” the most common design, refrigerant circulates between an indoor coil and a matching—meaning from the same brand—outdoor condenser with compressor (see illustration, below). The refrigerant cools the air, dehumidifying it in the process; a blower circulates air through ducts throughout the house. A thermostat maintains the temperature at the setting you select. A variation is the “heat pump,” a type of system that functions as heater and air conditioner.
Cut down on energy costs and prevent damage to your furnace by addressing a gas furnace that's overactive or short cycling. Besides the need for consistently comfortable temperatures, this issue could cause long-term safety issues to your home, making it very important to address. From a faulty thermostat to a dirty filter, there are several possible causes to investigate.
A contactor is a $25 mechanical relay that uses low-voltage power from the thermostat to switch 220-volt high-amperage current to the compressor and condenser fan. AC contactors can wear out and are at the top of the list of common air conditioning service failures. Even if your contactor is working, it pays to replace it every five years or so. Unscrew the old contactor before removing the wires. Then move the wires to the new unit (photo 6).
Contact/Relay -- Relays are electronically controlled switches that activate the various components of your HVAC system. They manage everything from the power going to the motor to automatic dampers, humidifiers, etc. Most of them are controlled by the thermostat. The most common failure for a relay is being stuck in the "open" position. Separated from its assigned contact point, it fails to complete the connection and send the message to whatever it was supposed to operate. This failure usually occurs from use over time. Each time a relay connects and sends its signal, the electrical arcing from point to point eventually causes wear and tear.
Vredevoogd Heating & Cooling Grand Rapids employs more than 80 people who are proud to work under the Vredevoogd Heating & Cooling banner. Each team member shares our company values for service excellence. All of our employees are intensely screened and background checked so that you have peace of mind when they enter your home. Moreover, our technicians are certified to work in the HVAC industry and provide the level of expertise that our customers expect from Vredevoogd Heating & Cooling. We back our technicians’ work and continue to make training a priority so that all of our techs are familiar with the latest HVAC models and advances. Our customers deserve the best, so the best is what we deliver to each and every job.
Ventilating or ventilation (the V in HVAC) is the process of exchanging or replacing air in any space to provide high indoor air quality which involves temperature control, oxygen replenishment, and removal of moisture, odors, smoke, heat, dust, airborne bacteria, carbon dioxide, and other gases. Ventilation removes unpleasant smells and excessive moisture, introduces outside air, keeps interior building air circulating, and prevents stagnation of the interior air.
If you're in need of heat repair, furnace repair or heating repair then call the Ashburn HVAC Services family-owned and operated HVAC contractor in Leesburg and Ashburn, VA. We owe all of our success to you, our Ashburn and Leesburg customers who support us and we want to thank you! The highest compliment we receive is the trust in your referral and we truly appreciate your support!
The main problem when installing a multi-split system is the laying of long refrigerant lines for connecting the external unit to the internal ones. While installing a separate split system, workers try to locate both units opposite to each other, where the length of the line is minimal. Installing a multi-split system creates more difficulties, since some of indoor units can be located far from the outside. The first models of multi-split systems had one common control system that did not allow you to set the air conditioning individually for each room. However, now the market has a wide selection of multi-split systems, in which the functional characteristics of indoor units operate separately from each other.
For more than sixty years, Nerthling's Heating and Air Conditioning has continued a tradition of superior customer service across Erie County, including Erie, Millcreek and Fairview.  Family owned and operated, we treat you, your home, and your comfort the way we would like to be treated.  This commitment to integrity extends to every service and product we provide.  Our goal is to deliver the highest rewards for your investment, whether you require installation, maintenance, or repair.  We offer a wide range of styles and sizes of equipment, services, and resources to help you achieve your goals for temperature control, air quality, and energy savings.
In the UK, the Ozone Regulations[62] came into force in 2000 and banned the use of ozone depleting HCFC refrigerants such as R22 in new systems. The Regulation banned the use of R22 as a "top-up" fluid for maintenance between 2010 (for virgin fluid) and 2015 (for recycled fluid). This means that equipment that uses R22 can still operate, as long as it does not leak. Although R22 is now banned, units that use the refrigerant can still be serviced and maintained.
There are a number of claims in the HVAC industry that make HVAC technicians sound like they know what they are doing, but the North American Technician Excellence (NATE) certification program is the only closed book examination and certification program, administered by a third party, that tests real world working knowledge of HVAC systems. That's why all of our service technicians complete and continue NATE certification training throughout their career with SMO.
Multiple inventions within this time frame preceded the beginnings of first comfort air conditioning system, which was designed in 1902 by Alfred Wolff (Cooper, 2003) for the New York Stock Exchange, while Willis Carrier equipped the Sacketts-Wilhems Printing Company with the process AC unit the same year. Coyne College was the first school to offer HVAC training in 1899.[12]
Hi John, Thanks for reaching out, we would be happy to help you connect with a pro for your project. You can submit a request to our pros here: www.homeadvisor.com, browse a list of pros that serve your area here: http://www.homeadvisor.com/c.html, or send your info to [email protected] and a project advisor will reach out to assist you. –HASupport

An important component of natural ventilation is air change rate or air changes per hour: the hourly rate of ventilation divided by the volume of the space. For example, six air changes per hour means an amount of new air, equal to the volume of the space, is added every ten minutes. For human comfort, a minimum of four air changes per hour is typical, though warehouses might have only two. Too high of an air change rate may be uncomfortable, akin to a wind tunnel which have thousands of changes per hour. The highest air change rates are for crowded spaces, bars, night clubs, commercial kitchens at around 30 to 50 air changes per hour.[17]


Trane central air conditioners are often billed as the “Cadillac of HVAC systems” and that’s because it’s one of the most reliable brands in the business. Trane AC is known for upholding warranties and offers a standard 10-year warranty that covers both parts and labor. Trane products are often pricier than other HVAC brands, but as the old saying goes, “You get what you pay for.”
There are a number of claims in the HVAC industry that make HVAC technicians sound like they know what they are doing, but the North American Technician Excellence (NATE) certification program is the only closed book examination and certification program, administered by a third party, that tests real world working knowledge of HVAC systems. That's why all of our service technicians complete and continue NATE certification training throughout their career with SMO.
As the name implies, a window air conditioner is typically installed in a window or custom opening in a wall. The Window AC can only cool small areas and are not intended to provide cooling to multiple rooms or zones. These air conditioners are manufactured as cool only or can provide both cooling and heating. An optional damper in the unit can provide fresh outdoor air if necessary.
Capacitors -- Capacitors help your HVAC motor start from a standstill. Over time they can weaken. As they weaken, they cause the motor to run hotter. This can shorten the life expectancy of your motor. Once a capacitor fails, the whole motor will stop working. You usually won't notice that a capacitor has weakened until your motor stops turning on.
Split ACs are used in larger application areas than window ACs. The split AC focuses on splitting the cold from the hot side of the system. The cold side has the cold coil and the expansion valve. This is usually placed inside a furnace or any other form of air handler. The handler blows air over the coil and the cooled air is distributed to various rooms in the building through the air ducts.
Honesty and integrity go a long way with me also pricing was very fair.....A-ok gets it done.... My a/c just stopped working after 12 a.m. I called 3 companies and no one was able to come out till the morning. I couldn't wait till morning due to the fact I have elderly people living with me. so I call A-ok and Tyler was the tech on call for the night. He was super helpful and friendly. Tyler was a few counties away but made the call to rush to my home after 12 am. And fix my unit. It was getting pretty hot inside my house. Turns out it was just a fuse that went bad. He was able to correct it in minutes. I'm thankful Tyler is a honest young man. He could have said anything to run up the bill but he didn't... it was just a blown fuse. I high recommend A-OK for service needs. The pricing was fair and matched up better than everyone else.... the difference which is huge was Tyler came out to do the repair where as every other company wanted me to wait till the morning. Thank you Tyler for getting my unit back in order and I'm happy to say they have my Business going forward....
Indoor Fan Motor -- Indoor fans circulate the air from your house and through the system. Age and dust buildup are the two biggest contributing factors to their failure. When they are starting to fail they will often make noise. Failure of the fan will result in no heating or cooling, and if it is not repaired soon, it can cause other components to fail.
Locally owned and family operated, M and M, Heating & Cooling, Plumbing & Electrical customizes solutions to perfectly fit your requirements and lifestyle. We specialize in a wide range of services including plumbing, water heating, indoor air quality, and residential and commercial temperature control. Our team of highly trained and certified technicians are fully licensed and insured, adhere to strict service procedures, and meet exacting standards of quality. Call on M and M, Heating & Cooling, Plumbing & Electrical at (720) 443-6119 for dedicated service throughout Longmont, CO & surrounding areas, and have confidence in a rewarding experience and long-term results. With over eighteen years of satisfied customers, we take great pride in a job done right.
The heat pump gained popularity in the 1950s in Japan and the United States.[13] Heat pumps can extract heat from various sources, such as environmental air, exhaust air from a building, or from the ground. Initially, heat pump HVAC systems were only used in moderate climates, but with improvements in low temperature operation and reduced loads due to more efficient homes, they are increasing in popularity in cooler climates.
This single phase 13 SEER sweat air conditioning This single phase 13 SEER sweat air conditioning system is designed for residential and commercial applications and consists of the outdoor condenser indoor cased coil and 30 ft. line set. The compact micro-channel condenser is charged with R-410A refrigerant and has a top air discharge. The cased coil is filled ...  More + Product Details Close
As a full-service heating contractor, we strongly encourage you to be vigilant with annual heating maintenance. Without proper maintenance, a heat pump, furnace or boiler might last only half as long as a well-maintained unit. Don’t tempt fate by skimping on annual service. We offer an economical, yet comprehensive maintenance agreement that we call our Cool Care Service Agreement. With our maintenance agreement you’ll receive:
Most of the air conditioners in residential buildings are in the form of split systems – only bigger. They have a cooling fan, a condenser coil and a compressor housed in a separate condensing unit. The evaporator coil is usually inside an air handler (indoor) unit normally installed on the furnace. When the furnace is electric, a blower is included in the system.
Fuses -- Anyone who has worked with electrical systems knows all about fuses and how they fail. They can burn out over time, may just be loose, or can blow out during an electrical storm or due to overload from another failed component. Of course, that's what they're supposed to do; they stop surges from going through and damaging the rest of the system. When a fuse fails, whatever system it was protecting will stop working.
Furnace & Heating repair, installation and maintenance provided by TRS Heating and Air Conditioning will keep your house cosy and your energy bills in check. If you’re in the area TRS Heating and Air Conditioning can make sure your home heating system is running at it’s maximum potential. Making sure your furnace and home heating is running efficiently is extremely important in providing your home with stable temperatures all year round.
How often you should clean your air ducts depends on your situation. If you or someone in the home has asthma or is acutely allergic to certain airborne materials or pollen, regular duct cleaning may be helpful. The Environmental Protection Agency doesn’t have an official position on the necessity of air duct cleaning unless the ducts have been contaminated by rodents, insects or mold, or you are aware of particles blowing out through the vents. The EPA recommends you have your air ducts cleaned on an as-needed basis. The National Air Duct Cleaners Association (NADCA) suggests having air ducts cleaned every three to five years.

Service Experts Heating and Air Conditioning was founded on the basis of providing customers with the best heating and cooling practices in the industry. Since its inception, Service Experts has been dedicated to community, providing the top of the line HVAC products and services in your area. If you want more information about your local HVAC leaders, call us at 866-397-3787 or set up an appointment with us online.
Air conditioning can also be provided by a process called free cooling which uses pumps to circulate a coolant (typically water or a glycol mix) from a cold source, which in turn acts as a heat sink for the energy that is removed from the cooled space. Common storage media are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter boreholes, equipped with heat exchanger. Some systems with small storage capacity are hybrid systems, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added because the temperature of the storage gradually increases during the cooling season, thereby declining its effectiveness.
Ground source, or geothermal, heat pumps are similar to ordinary heat pumps, but instead of transferring heat to or from outside air, they rely on the stable, even temperature of the earth to provide heating and air conditioning. Many regions experience seasonal temperature extremes, which would require large-capacity heating and cooling equipment to heat or cool buildings. For example, a conventional heat pump system used to heat a building in Montana's −70 °F (−57 °C) low temperature or cool a building in the highest temperature ever recorded in the US—134 °F (57 °C) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air temperatures. A few feet below the earth's surface, however, the ground remains at a relatively constant temperature. Utilizing this large source of relatively moderate temperature earth, a heating or cooling system's capacity can often be significantly reduced. Although ground temperatures vary according to latitude, at 6 feet (1.8 m) underground, temperatures generally only range from 45 to 75 °F (7 to 24 °C).
You can install the greatest HVAC system ever built, but if your house is not insulated well, it's only going to end up costing you more money. Older homes may have fiberglass insulation that has broken down due to pests, moisture, or improper installation. Spray foam insulation can be damaged by careless repair or modification work or can be improperly installed. If your insulation in compromised, your attempts to save money and be comfortable will be in vain.
Cold aisle is a layout design for server racks and other computing equipment in a data centre. Cold aisle data center design involves lining up server racks in alternating rows with cold air intakes facing one way and hot air exhausts facing the other. The rows composed of rack fronts are called cold aisles. See Data Centre Aisle Containment for more information.

Wiring up the thermostat is usually pretty straightforward if an old one is being replaced. If a thermostat is being put in where one had never been before, that could involve running new wiring. The placement of the thermostat is also important so that its sensors can get an accurate reading of the temperature. A thermostat that is blocked by a bookcase or other large furniture will not get a good reading and will not perform efficiently.
Heat pipe heat exchangers or run-around coils perform a similar function when humidity control is required. Two heat exchanger are placed in the air stream, one upstream of the cooling coil and the other downstream of the cooling coil. These heat exchangers are connected together with piping. A heat transfer fluid, whether it be water or refrigerant, is either pumped or gravity fed from one heat exchanger to the other. The heat exchanger down stream of the cooling coil (re-heat coil) cools the liquid medium inside the heat exchanger and heats the air passing over the heat exchanger. The cold liquid inside the heat exchanger is moved to the heat exchanger upstream of the cooling coil (pre-cool coil) where it pre-cools the air passing over the heat exchanger and warms the liquid passing through the heat exchanger. The affect of a heat pipe or run-around coil is to reduce the sensible heat capacity of the AC system. The latent capacity of the AC system increases if direct-expansion equipment is used or remains relatively constant if chilled water equipment is used. Since the sensible capacity of the AC system has been reduced, the system must run longer to meet the thermostat set point thereby removing more moisture.
Sometimes a heating and air conditioning system just needs to be repaired rather than completely replaced. You may need air conditioning repair services if there is leaking around the outside unit, the air coming into the house isn't hot or cool enough, the unit is short-cycling or constantly turning on and off, using the system is consistently resulting in higher-than-normal energy bills, or if there is excessive noise during startup and operation.
×