"Jorge Mondragon did a fantastic job installing a new upstairs AC and furnace. His price was close to the best that I received, and after seeing the positive reviews on Thumbtack, I decided to give him the job. He came in with two other crewman and worked about a half day to get the job done. They used tarps on the floor and covered the entire section they walked on during the install, including the stairs. The new AC works great, although the real test will come when the brutal summer kicks in. I'll update my review once I have a few months on the unit. The install job looked thorough and well done. Professional, polite, well-spoken, and hardworking. This is my go-to company for all future HVAC needs and I'll be recommending him to everyone I know."
If you need a furnace repaired or an air conditioner serviced, we'll send a local technician out to diagnose the specific problem and recommend solutions for you and your family. There will be a diagnostic fee for the visit, and any specific repairs will be an additional charge. If replacing your system is the best solution, the fee for the diagnosis will be credited toward the purchase and install of a new system.
In addition, if water is condensed in the room, the amount of heat previously needed to evaporate that water also is re-released in the room (the latent heat of vaporization). The dehumidification process is the inverse of adding water to the room with an evaporative cooler, and instead releases heat. Therefore, an in-room dehumidifier always will warm the room and reduce the relative humidity indirectly, as well as reducing the humidity directly by condensing and removing water.
In a chilled water system, liquid water is pumped throughout the building to “chilled water coils”. Since the liquid water needs to be at a cold temperature, a “cooling plant” is required. The plant is typically referred to as a chiller plant. Vapor compression equipment in the plant, similar to that described in “How does my AC work”, cool water to a cold temperature and pump the cold water to air-to-water heat exchangers where needed.
When our Denver heating company provides you with maintenance checks before the cold of winter sets in, you will be saving money in several different ways. One of the benefits of a maintenance plan is our technicians will be less likely to have to make repairs throughout the year as long as the system is properly maintained. Our Denver heating company will have your system running at its most efficient, helping to reduce your utility bills each month. An added benefit of a more efficiently running system is the positive environmental effect that it will have.
Electronically Commutated (EC) fans use brushless DC motors which include in-built electronics to convert the AC supply to DC without the need for a separate DC supply. EC fans provide a more efficient (up to 30%) means of airflow through Precision Air Conditioning (PAC) units with the additional benefit of variable speed control via an output signal from the unit controller. Also see EC Fan upgrades.
BGE HOME HVAC repair technicians are thoroughly trained and certified to work on all major brands of heating and air conditioning equipment. When your system breaks down and needs a heating and air conditioning repair, you want to call someone you can trust. Need air conditioning service in the middle of the night? Emergency heating and cooling HVAC service is available 24 hours a day by calling 888-243-4663.
In addition to providing repairs for A/C and HVAC systems, we can also repair almost any heating system. Just tell us what the trouble is and we will run the appropriate tests and checks to find out what needs doing to get your heating operational again. We use high-grade equipment and tools for every job we complete, helping to give you the top-quality results you’re looking for.
The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.

Air conditioners often use a fan to distribute the conditioned air to an occupied space such as a building or a car to improve thermal comfort and indoor air quality. Electric refrigerant-based AC units range from small units that can cool a small bedroom, which can be carried by a single adult, to massive units installed on the roof of office towers that can cool an entire building. The cooling is typically achieved through a refrigeration cycle, but sometimes evaporation or free cooling is used. Air conditioning systems can also be made based on desiccants (chemicals which remove moisture from the air) and subterraneous pipes that can distribute the heated refrigerant to the ground for cooling.[2]
HVAC is an important part of residential structures such as single family homes, apartment buildings, hotels and senior living facilities, medium to large industrial and office buildings such as skyscrapers and hospitals, on ships and submarines, and in marine environments, where safe and healthy building conditions are regulated with respect to temperature and humidity, using fresh air from outdoors.

There are a number of claims in the HVAC industry that make HVAC technicians sound like they know what they are doing, but the North American Technician Excellence (NATE) certification program is the only closed book examination and certification program, administered by a third party, that tests real world working knowledge of HVAC systems. That's why all of our service technicians complete and continue NATE certification training throughout their career with SMO.

SEER is useful for comparing one model to another much in the same way that a car's calculate MPG is useful. It's not an accurate prediction of exactly how efficient the system is, but it can tell you which one is more efficient. Also, since SEER is based on a "cooling season", what region you live in will determine how long or short your cooling season is.


A specialized air conditioner that is used only for dehumidifying is called a dehumidifier. It also uses a refrigeration cycle, but differs from a standard air conditioner in that both the evaporator and the condenser are placed in the same air path. A standard air conditioner transfers heat energy out of the room because its condenser coil releases heat outside. However, since all components of the dehumidifier are in the same room, no heat energy is removed. Instead, the electric power consumed by the dehumidifier remains in the room as heat, so the room is actually heated, just as by an electric heater that draws the same amount of power.

Keep in mind that ducts used for heating might not be the right size or in the right location for optimal cooling. Your contractor should ensure that duct sections are properly sized and that there are enough supply registers to deliver sufficient air to the right spots. Undersized ductwork can make for inefficient and noisy operation. Here’s how to keep yours humming:
Fresh-Aire UV is an innovation leader in the field of indoor air quality. Our award-winning UV light and carbon products fight mold, bacteria, viruses and odors in commercial and residential HVACR systems. Our products include Blue-Tube UV®, the world’s most popular germicidal UV light, the revolutionary APCO® PCO/carbon whole-house air purifier, and Mini UV the first UV light system designed specifically for mini-split AC systems.
Packaged terminal air conditioner (PTAC) systems are also known as wall-split air conditioning systems.[36] They are ductless systems. PTACs, which are frequently used in hotels, have two separate units (terminal packages), the evaporative unit on the interior and the condensing unit on the exterior, with an opening passing through the wall and connecting them. This minimizes the interior system footprint and allows each room to be adjusted independently. PTAC systems may be adapted to provide heating in cold weather, either directly by using an electric strip, gas, or other heater, or by reversing the refrigerant flow to heat the interior and draw heat from the exterior air, converting the air conditioner into a heat pump. While room air conditioning provides maximum flexibility, when used to cool many rooms at a time it is generally more expensive than central air conditioning.
This single phase 13 SEER sweat air conditioning This single phase 13 SEER sweat air conditioning system is designed for residential and commercial applications and consists of the outdoor condenser indoor cased coil and 30 ft. line set. The compact micro-channel condenser is charged with R-410A refrigerant and has a top air discharge. The cased coil is filled ...  More + Product Details Close
A mini-split system typically supplies air conditioned and heated air to a single or a few rooms of a building.[38] Multi-zone systems are a common application of ductless systems and allow up to 8 rooms (zones) to be conditioned from a single outdoor unit. Multi-zone systems typically offer a variety of indoor unit styles including wall-mounted, ceiling-mounted, ceiling recessed, and horizontal ducted. Mini-split systems typically produce 9,000 to 36,000 Btu (9,500–38,000 kJ) per hour of cooling. Multi-zone systems provide extended cooling and heating capacity up to 60,000 Btu's.
Tired of dealing with an inoperable furnace? Or, maybe your heating system is only heating half the rooms in your home? Whether you need a new heating system installed or an existing unit repaired, there’s only one name to know—ABC Plumbing, Heating, Cooling & Electric. With more than six decades of experience handling Chicago’s heating problems, our team at ABC has the experience and know-how to get any heating issue diagnosed and resolved quickly and efficiently.
×