Air Conditioner Repair Philadelphia trust, Heater Repair by Philadelphia’s top rated Heating and Cooling Company. HVAC Philly is a full service HVAC Repair services proudly serving residences and businesses in the Philadelphia, Bucks and Montgomery county area since 1994. At HVAC Philly we offer 24-hour emergency Air Conditioning Repair and Heating Repair service, as a greater Philadelphia licensed HVAC contractor, we install and service air conditioning and heating systems. In addition, we offer preventative maintenance plans, same day AC Repair, Heater replacement and custom ductwork.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
We bought 2 top of the line Lennox HAC for $29,000 less about $3,500 rebates, thinking they would at least last 10 years. Well, after 6 years, the system leaked. We are paying $1,700 to fix that leak. We thought at least it is still under warranty - yes BUT - the warranty covered $15 & the rest we were up for ,even though they advertise 10 year warranty. We are trying to sell & move out of high cost southern Calif & have looked at 20+ places in Arizona. Most of the houses we looked at were built from 1998 to 2005. We asked if the HAC was original & in most case it was - even though the highs were 115 to 120 & the lows 90F - versus where we live the highs run 85 to 95 & the lows are in the 60s. I asked the repairman WHY ours went out at 6 years. He replied that they just do not build them the same anymore. In Arizona, I did not see any Lennox - mostly Trane or Carrier. We had Fujistu in Australia which were fantastic - nothing went wrong in the 9 years we had them. Also, they had full induction motors not like the energy consuming 2 stage motors in Lennox. Maybe the Japanese built Fujusita still builds quality & the warranty is meaningful?
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
Rheem's RRNL features a scroll compressor with fewer moving parts and less noise than traditional reciprocating compressors. A louvered compressor compartment protects the compressor from the elements and from debris that can shorten the life of the compressor. The Classic series continues to be one of their best sellers, with the addition of the Comfort Alert diagnostics module integrated to assist technicians in the event your system needs repair. 2-5 tons, 13 SEER, 80% AFUE.
Many homes have a forced-air HVAC system. Both the heating and the central air conditioning units share a ductwork system where they either push in or pull out warm or cooled air. There are also heating and cooling systems that don’t require ductwork — such as ductless mini-splits — but work on the same principles of heat exchange. The national average to hire an HVAC specialist is $2,920-$3,670, with costs varying depending on the work you need done and the equipment you are installing.
A type of air conditioning system using a water/glycol solution as a condensing medium. Typically, the glycol-cooled condenser is located inside the air conditioner with the rest of the refrigeration components.  Water/glycol is piped to the unit from a drycooler or other suitable source. The glycol keeps the solution from freezing during winter operation.

Has your Dallas home air conditioning system stopped giving you the cool comfort you have come to expect? Or maybe you have decided it’s time to upgrade from a window unit to a whole home cooling solution. Whatever the case may be, you can rely on the expertise, experience, and know-how of the professionals at Baker Brothers Plumbing & Air Conditioning to complete your installation fast and correctly.
In a thermodynamically closed system, any power dissipated into the system that is being maintained at a set temperature (which is a standard mode of operation for modern air conditioners) requires that the rate of energy removal by the air conditioner increase. This increase has the effect that, for each unit of energy input into the system (say to power a light bulb in the closed system), the air conditioner removes that energy.[30] To do so, the air conditioner must increase its power consumption by the inverse of its "efficiency" (coefficient of performance) times the amount of power dissipated into the system. As an example, assume that inside the closed system a 100 W heating element is activated, and the air conditioner has a coefficient of performance of 200%. The air conditioner's power consumption will increase by 50 W to compensate for this, thus making the 100 W heating element cost a total of 150 W of power.
Indoor Coil -- The indoor coil is a heat transfer device. It absorbs the heat from the inside of the house and passes it on to the refrigerant and is pumped outside. Dust that builds up on the coil can hamper its ability to absorb heat. High heat transference coils use very thin metal. Airborne chemicals can cause corrosion which leads to leaks. The constant vibration of the compressor can also cause solder joints to weaken and leak. An indoor coil may operate for weeks with a tiny leak, and you may not notice the loss in performance right away. As soon as a leak is made known, it should be replaced or repaired immediately.
Heat pipe heat exchangers or run-around coils perform a similar function when humidity control is required. Two heat exchanger are placed in the air stream, one upstream of the cooling coil and the other downstream of the cooling coil. These heat exchangers are connected together with piping. A heat transfer fluid, whether it be water or refrigerant, is either pumped or gravity fed from one heat exchanger to the other. The heat exchanger down stream of the cooling coil (re-heat coil) cools the liquid medium inside the heat exchanger and heats the air passing over the heat exchanger. The cold liquid inside the heat exchanger is moved to the heat exchanger upstream of the cooling coil (pre-cool coil) where it pre-cools the air passing over the heat exchanger and warms the liquid passing through the heat exchanger. The affect of a heat pipe or run-around coil is to reduce the sensible heat capacity of the AC system. The latent capacity of the AC system increases if direct-expansion equipment is used or remains relatively constant if chilled water equipment is used. Since the sensible capacity of the AC system has been reduced, the system must run longer to meet the thermostat set point thereby removing more moisture.
Concrete Blocks -- Concrete blocks are used in foundations and are often found in full basements. Insulating the spaces in the blocks is not the way to insulate them as the heat energy will travel along the concrete itself. The best way to insulate with concrete blocks is to use insulated concrete blocks, which have polystyrene incorporated into them.
A multi-split system[44] is a conventional split system, which is divided into two parts (evaporator and condenser) and allows cooling or heating of several rooms with one external unit. In the outdoor unit of this air conditioner there is a more powerful compressor, ports for connecting several traces and automation with locking valves for regulating the volume of refrigerant supplied to the indoor units located in the room.
We are open from 7am to 10pm every weekday and from 7am to 8pm on weekends. We book appointments in a 2 hour arrival window and call 30-45 mins before we arrive so you do not have to sit around waiting. It is often possible to schedule your appointment in the evening or morning hours to avoid conflicting with your work schedule. Are you looking for service today? Give us a call or click on one of the Schedule Service buttons found on the top and left sides of this page to contact us today.

Bonney’s NATE certified technicians will troubleshoot and repair your furnace for safe and reliable operation. Our technicians use state of the art tools including video inspection cameras and exhaust gas analyzers to perform thorough, comprehensive diagnostics when equipment is broken. Furthermore, we arrive in a “warehouse on wheels” stocked with many parts to get your furnace repaired as quickly as possible.  For an unexpected heater repair Bonney offers financing to make your comfort affordable.
Understanding all of your home’s heating and cooling parts for the North America climate is probably a little unrealistic, but there are a few things that can be helpful to you as a homeowner. If you’d like more information about your current system and whether an air handler or air conditioner is right for your home, give the experts at Service Experts a call at 866-397-3787 or set up a free appointment online today.
In the UK, the Ozone Regulations[62] came into force in 2000 and banned the use of ozone depleting HCFC refrigerants such as R22 in new systems. The Regulation banned the use of R22 as a "top-up" fluid for maintenance between 2010 (for virgin fluid) and 2015 (for recycled fluid). This means that equipment that uses R22 can still operate, as long as it does not leak. Although R22 is now banned, units that use the refrigerant can still be serviced and maintained.
It's a little awkward, so we'll get straight to the point: This Monday we humbly ask you to defend Wikipedia's independence. We depend on donations averaging about $16.36, but 99% of our readers don't give. If everyone reading this gave $2.50, we could keep Wikipedia thriving for years to come. The price of your Monday coffee is all we need. When we made Wikipedia a non-profit, people warned us we'd regret it. But if Wikipedia became commercial, it would be a great loss to the world. Wikipedia is a place to learn, not a place for advertising. It unites all of us who love knowledge: contributors, readers and the donors who keep us thriving. The heart and soul of Wikipedia is a community of people working to bring you unlimited access to reliable, neutral information. Please take a minute to help us keep Wikipedia growing. Thank you.
A contactor is a $25 mechanical relay that uses low-voltage power from the thermostat to switch 220-volt high-amperage current to the compressor and condenser fan. AC contactors can wear out and are at the top of the list of common air conditioning service failures. Even if your contactor is working, it pays to replace it every five years or so. Unscrew the old contactor before removing the wires. Then move the wires to the new unit (photo 6).
Whether you’re looking to have a heat pump installed for the first time or think it’s time for an upgrade to your current system, Goettl Air Conditioning is the company to call. We offer a great lineup of Phoenix heat pumps and will make sure that the one we install in your home is the recommended match to your home’s dimensions and your family’s needs.
The basic concept behind air conditioning is said to have been applied in ancient Egypt, where reeds were hung in windows and were moistened with trickling water. The evaporation of water cooled the air blowing through the window. This process also made the air more humid, which can be beneficial in a dry desert climate. In ancient Rome, water from aqueducts was circulated through the walls of certain houses to cool them. Other techniques in medieval Persia involved the use of cisterns and wind towers to cool buildings during the hot season.[5]
Nerthlings Heating and Air Conditioning is proud to be rated as Erie, PA’s leading heating and cooling company. We’ve been serving Erie PA and the surrounding areas for over 60 years, handling all of their HVAC needs. For furnace repair, furnace service, or a new heating system installation at your home/business, Nerthling’s is the company to call if you want the job done right. We are also experts at AC repair, service & installation, as well as generator installation. Our other services include boiler repair and service, geothermal HVAC, heat pumps and ductless heating & air conditioning. To learn more about our high-quality HVAC services, give us a call today at 814-240-2297!
Central home air conditioner service systems consist of two major components: a condensing unit that sits outside your house, and the evaporator coil (often referred to as an A-coil) that sits in the plenum of your furnace or air handler. The refrigerant in the A-coil picks up the heat from your home and moves it to the outdoor condensing unit. The condensing unit fan blows outside air through the condensing coil to remove the heat. The condensing unit houses the three parts replaceable by a DIYer: the contactor, the start/run capacitor(s) and the condenser fan motor. The condensing unit also houses the compressor, but only a pro can replace that. The A-coil has no parts that can be serviced by a DIYer.

We are totally committed to your comfort. Our quality technicians set our business apart by providing the best and most professional service in the area. We are fully trained on today’s HVAC technology systems and methods, so when we are in your home or business, you can rest assured that we’ll work quickly and skillfully toward your total comfort.
Induced draft furnaces use a small fan to draw the combustion gasses from the combustion chamber and out of the house through the flue (chimney). This system is more reliable and safer than old conventional furnaces, which relied on a natural draft coming in from an opening at the front of the furnace. Induced draft furnaces use either an intermittent pilot (IP) or hot surface ignition (HSI) instead of a standing pilot light. The combination of electronic ignition, electronic controls, and artificially created draft improves the efficiency of induced draft furnaces over older conventional models. 
Heaters exist for various types of fuel, including solid fuels, liquids, and gases. Another type of heat source is electricity, normally heating ribbons composed of high resistance wire (see Nichrome). This principle is also used for baseboard heaters and portable heaters. Electrical heaters are often used as backup or supplemental heat for heat pump systems.
*Residential Service call's subject to $119.00 travel and diagnostic fee, Commercial Service call's subject to a $149.00 travel and diagnostic fee. Once diagnosed, necessary repairs will be quoted in accordance with standard flat rate repair price. Repair and quoted repair price may be accepted or declined by the customer at that time. Travel and Diagnostic fee will still apply in case customer declines repair. All calls are C.O.D. Overtime rates for Residential Service are $169.00, overtime rates for Commercial services are $179.00.  These rates are for services performed after normal business hours Monday through Friday 8am-4:30pm.
Air Conditioning Parts is an international AC Parts distributor specializing in OEM wholesale A/C Parts for all air conditioner makes and models. All of our parts and equipment are available at factory direct pricing! For almost 30 years, our exceptional level of service and responsiveness coupled with our experienced air conditioning parts specialists have allowed us to establish solid long term relationships with thousands of A/C service companies, hotel and motel owners, apartment owners and management companies, and numerous other industry professionals who need and count on a knowledgeable AC parts supplier for the right part, overnight delivery and the best possible prices for all types of air conditioning parts and AC equipment. Professionals know they can depend on Air Conditioner Parts! Let us earn your trust. Call us for any A/C Part or any A/C Equipment at 800-525-3572.

A mini-split system typically supplies air conditioned and heated air to a single or a few rooms of a building.[38] Multi-zone systems are a common application of ductless systems and allow up to 8 rooms (zones) to be conditioned from a single outdoor unit. Multi-zone systems typically offer a variety of indoor unit styles including wall-mounted, ceiling-mounted, ceiling recessed, and horizontal ducted. Mini-split systems typically produce 9,000 to 36,000 Btu (9,500–38,000 kJ) per hour of cooling. Multi-zone systems provide extended cooling and heating capacity up to 60,000 Btu's.
Our team members are all highly-qualified and our HVAC products are the best available on the market. We want to be your first choice when you are looking for an air conditioner and heating company in Toronto. City Air Conditioning and Heating is always looking for more advanced and better ways to help serve our valued customers because we are committed to meeting all of your Toronto air conditioning and heating needs. We would love to hear from you and for you to let us know what we can do better to serve you and your needs.
Our fully trained and certified heating technicians have been repairing installing furnaces, heating systems and heat pumps in Smyrna and the Atlanta area since 1966.  We offer 24 hour emergency service for unexpected heating system break downs.  We can provide expert maintenance and repair on your current heating system or help you select a new, high-efficiency heating system from our wide range of furnaces.
Since the 1980s, manufacturers of HVAC equipment have been making an effort to make the systems they manufacture more efficient. This was originally driven by rising energy costs, and has more recently been driven by increased awareness of environmental issues. Additionally, improvements to the HVAC system efficiency can also help increase occupant health and productivity.[21] In the US, the EPA has imposed tighter restrictions over the years. There are several methods for making HVAC systems more efficient. 
×